Agilent / Varian / Dynamax / Rainin HPLC Autosamplers
  • Varian_ProStar410_View1
  • Varian_ProStar410_View2
  • Varian_ProStar410_View3
  • Varian_ProStar410_View4

Agilent / Varian / Dynamax / Rainin HPLC Autosamplers

Features

  • Compact and Easy to Use
  • Integrated Column Oven
  • Interchangeable Sample Tray Design
  • Nine Injection Methods Stored in Memory
  • Vial Detection Circuitry
  • Excellent Reproducibility with Low Carryover

View our selection of these items below.




Contact Us
Share:



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition.

Part Number: 900
Firmware Rev.: 1.01
Syringe Volume: 1mL
Injection Loop Volume: 100µL
Tubing Needle Volume: 45µL
Buffer Tubing Volume: 2000µL
(8) 12x2mL Vial Segment Trays
Date of Manufacture: 1996
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition.

Part Number: 900
Firmware Rev.: 1.01
Syringe Volume: 1mL
Injection Loop Volume: 1mL
Tubing Needle Volume: 45µL
Buffer Tubing Volume: 2000µL
(8) 12x2mL Vial Segment Trays
Date of Manufacture: 1996
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition.

Part Number: 900
Syringe Volume: 1mL
Injection Loop Volume: 100µL
Tubing Needle Volume: 15µL
(8) D-Type Vial Segment Trays (Vial diameter: 7mm)
Max Vial Height (including cap): 47mm
Min Vial Height (including cap): 32mm
Date of Manufacture: 1995
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition.

Part Number: 900
Firmware Rev.: 1.01
Syringe Volume: 250µL
Injection Loop Volume: 100µL
Tubing Needle Volume: 15µL
Buffer Tubing Volume: 500µL
(4) A-Type Vial Segment Trays (Vial diameter: 12mm)
(4) C-Type Vial Segment Trays (Vial diameter: 22mm)
Max Vial Height (including cap): 47mm
Min Vial Height (including cap): 32mm
Date of Manufacture: 1996
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition.

Part Number: 900
Injection Loop Volume: 100µL
Tubing Needle Volume: 15µL
Buffer Tubing Volume: 500µL
(6) A-Type Vial Segment Trays (Vial diameter: 12mm)
Max Vial Height (including cap): 47mm
Min Vial Height (including cap): 32mm
Date of Manufacture: 1995
Power Input: 115-120V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

This unit has Tray Cooling Installed.

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition.

Part Number: 900
Firmware Rev.: 1.01
Syringe Volume: 15µL
Injection Loop Volume: 200µL
Tubing Needle Volume: 15µL
Buffer Tubing Volume: 500µL
(8) A-Type Vial Segment Trays (Vial diameter: 12mm)
Max Vial Height (including cap): 47mm
Min Vial Height (including cap): 32mm
Date of Manufacture: 1996
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition.

Part Number: 900
Firmware Rev.: 1.01
Injection Loop Volume: 200µL
Tubing Needle Volume: 15µL
Buffer Tubing Volume: 2000µL
(6) A-Type Vial Segment Trays (Vial diameter: 12mm)
(1) B-Type Vial Segment Tray (Vial diameter: 15mm)
(1) C-Type Vial Segment Tray (Vial diameter: 22mm)
Max Vial Height (including cap): 47mm
Min Vial Height (including cap): 32mm
Date of Manufacture: 1997
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-1A Automatic Sample Injector is used and in excellent condition. This unit does not have a front assembly cover. This does not affect the unit operation. The unit also does not include an injection needle or buffer tube.

Part Number: 900
Firmware Rev.: 1.01
Syringe Volume: 10mL
Injection Loop Volume: 5mL
(8) A-Type Vial Segment Trays (Vial diameter: 12mm)
Max Vial Height (including cap): 47mm
Min Vial Height (including cap): 32mm
Date of Manufacture: 1996
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

Injector Needle and Buffer Tubing sold separately.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin AI-3 Automatic Sample Injector is used and in excellent condition.

Part Number: 816
Firmware Rev.: 1.00
Injection Loop Volume: 5mL
Tubing Needle Volume: 15µL
48 Sample Tray
Date of Manufacture: 1995
Power Input: 115-230V

View Photo of the internal tubing with front cover raised.

Varian Dynamax AI-3 Datasheet (pdf)

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Agilent / Varian / Dynamax / Rainin AI-96 Automatic Sample Injector is used an in excellent condition. This unit is missing a small panel on one side; however, this does not affect the units functionality.

Part Number: 920
Firmware Rev.: 2.03
Syringe Volume: 500uL
Injection Loop Volume: 200µL
Tubing Needle Volume: 15µL
Buffer Tubing Volume: 500µL
(4) Vial Segment Trays
Date of Manufacture: 1998
POwer Input: 115/230V
Size: 17.3 in. x 11 in. x 16 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin Model AI-200 Autosampler is used and in excellent condition.

Model Number: 830
Firmware Rev.: 1.06
Syringe: 250uL
Injection Loop Volume: 10uL
Tubing Needle Volume: 15uL
Buffer Tubing Volume: 500uL
Date of Manufacture: 1997
Power Input: 115-230V
Size: 13.4 in. x 11.8 in. x 19.7 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin Model AI-200 Autosampler is used and in excellent condition.

Model Number: 830
Firmware Rev.: 2.00
Syringe: 250uL
Injection Loop Volume: 10uL
Tubing Needle Volume: 15uL
Buffer Tubing Volume: 500uL
Date of Manufacture: 1997
Power Input: 115-230V
Size: 13.4 in. x 11.8 in. x 19.7 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin Model AI-200 Autosampler is used and in excellent condition.

Model Number: 830
Firmware Rev.: 1.06
Injection Loop Volume: 10uL
Date of Manufacture: 1997
Power Input: 115-230V
Size: 13.4 in. x 11.8 in. x 19.7 in. (H x W x D)

View Photo of the internal tubing with front cover raised.
View Photo of broken drain wash position tube.

Injector Needle, Syringe, and Tubing for Needle and Buffer sold separately.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin Model AI-200 Autosampler is used and in excellent condition.

Model Number: 830
Firmware Rev.: 1.06
Injection Loop Volume: 100uL
Date of Manufacture: 1997
Power Input: 115-230V
Size: 13.4 in. x 11.8 in. x 19.7 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

Injector Needle, Syringe, and Tubing for Needle and Buffer sold separately.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian ProStar Model 410 HPLC Autosampler is used, and in excellent condition.

Part Number: 0393529005 - Preparitive Autosampler
24 x 10mL Vial Sample Tray
Firmware Rev.: 2.06
Syringe: 2.5mL
Injection Loop Volume: 10mL
Tubing Needle Volume: 45uL
Buffer Tubing Volume: 2000uL
Date of Manufacture: 9/2002

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian ProStar Model 410 HPLC Autosampler is used, and in excellent condition.

Part Number: 0393529004 - Biocompatible Autosampler with Cooling Option
96 x 2.5mL Vial Sample Tray
Firmware Rev.: 2.01
Syringe: 250uL
Injection Loop Volume: 100uL
Tubing Needle Volume: 15uL
Buffer Tubing Volume: 500uL
Date of Manufacture: 6/2000

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian ProStar Model 420 HPLC Autosampler is used and in excellent condition.

Part Number: 393528901 - Standard Autosampler
160 x 0.5mL Vial Sample Tray
Firmware Rev.: 1.01
Injection Loop Volume: 20uL
Tubing Needle Volume: 15uL
Buffer Tubing Volume: 500uL
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of side view.
View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian ProStar Model 420 HPLC Autosampler is used and in excellent condition.

Part Number: 393528901 - Standard Autosampler
160 x 0.5mL Vial Sample Tray
Firmware Rev.: 1.01
Injection Loop Volume: 50uL
Tubing Needle Volume: 15uL
Buffer Tubing Volume: 500uL
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of side view.
View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.



This Varian / Dynamax / Rainin 920 Autosampler is used and in excellent condition.

Part Number: 920
Firmware Rev.: 2.03
Syringe Volume: 250µL
Injection Loop Volume: 200µL
Tubing Needle Volume: 15 µL
Buffer Tubing Volume: 500 µL
(1) Rectangular 8x6 Vial Tray
Date of Manufacture: 1998
Power Input: 115-230V
Size: 17.3 in. x 11 in. x 21.3 in. (H x W x D)

View Photo of the internal tubing with front cover raised.

If you require a different loop volume or tray configuration, please contact us for pricing and availability.


  • Description
  • Tech Specs
  • Datasheets / Manuals 
Contact Us
Share:

Description

The ProStar 410 AutoSampler offers the best of both worlds. It is intelligent for research applications yet rugged enough for routine quality control work. With Pressure Assisted Sampling Aspiration (PASA), the 410 AutoSampler applies pressure within the vial while the sample is withdrawn by a high-resolution syringe. Air bubbles and in-vial vacuum problems are eliminated resulting in excellent reproducibility.

The 410 AutoSampler’s three injection modes combine flexibility, ease-of-use, and precision. Choose from:
Full Loop — Overfills the sample loop for maximum precision.
Partial Loop — Program variable injection volumes easily.
Microliter Pickup — Withdraws the exact amount to be injected without sample loss.

The compact design with integrated column oven saves bench space. Access to the syringe, injector, and needle is easy with the lift-up front panel. The electronic GLP log book tracks syringe, injector, and needle information for timely, preventive maintenance.

Product Family: Varian ProStar 420 Autosampler, Varian ProStar 420, ProStar 420, ProStar 420 Autosampler, ProStar-420, Varian ProStar 410 Autosampler, Varian ProStar 410, ProStar 410, ProStar 410 Autosampler, ProStar-410, Dynamax AI-200 Autosampler, Dynamax AI200 Autosampler, Dynamax AI 200 Autosampler,Dynamax AI-200, Dynamax AI200, Dynamax AI 200, AI-200 Autosampler, AI200 Autosampler, AI 200 Autosampler,
Contact Us
Share:

Specifications


Related Equipment / Accessories