6 / 6 Results
Items/Page
Hirayama HV-85 Automatic High Pressure Autoclave
This Hirayama HV-85 Automatic High Pressure Autoclave is used and in excellent condition.

Features:
• Fused for 220 VAC operation
(...)
• (2) Large Sterilizing Baskets as Shown Here
• (1) Small Sterilizing Basket, Manual and Protective Gloves as Shown Here

Hobart Corporation LXiH Dishmachine
This Hobart Corporation LXiH Dishmachine is used and in excellent condition.

Configuration:
• Rated Amps: 37.7
• Maximum Prospective Devices: 50
(...)
• Net Weight: 210 lbs
• Pump: Centrifugal-Type, Horizontally Mounted, 54 gpm capacity
• Tank Capacity: 3 Gallons
• Electric Booster Heater: 6 kW
• Racks per Hour Rate: 30

Parts and Accessories:
• 49 Slot Glass Rack
• Dish Rack

View Photo of racks stacked.
View Photo of racks side by side.


CellPoint Scientific Germinator 500 Dry Sterilizer
This CellPoint Germinator 500 Dry Sterlizer is used and in excellent condition. This unit does not contain any glass beads.

Tuttnauer 2540E Table-Top Autoclave
Configuration:
• Chamber Volume: 23 Liter
• Standard Cassettes Capacity: 3 Full / 3 Half
(...)
• (4) Tray Capacity

Accessories Included:
• (1) Tray; Part Number: TRY240-0001
• Tray Holder; Part Number: TRH254-0001

Part Number: 80525

View Photo of interior.

Tuttnauer 5596 SP-1 55 Compact Series Autoclave
This Tuttnauer 5596 SP-1 55 Compact Series Autoclave is used and being sold without warranty. This unit was removed from a production facility. Our workplace does not have facility steam to fully(...) test this unit, and have to sell the item untested / as-pictured.

This unit includes a spare autoclave door gasket, two spare printer paper rolls, and a pull-out tray.

Facility Requirements:

• Maximum Ambient Temperature: 40 C
• Maximum Humidity: 80%
• Do not use the Autoclave in the presence of dangerous gases and vapors

Steam Requirements:

• Building Supply Pressure: 4-6 bar (50-80 psi)
• Maximum distance of Steam Trap from Autoclave: 2 meters
• Steam Inlet Pipe Diameter: 1/2 inch

Air Requirements:

• Building Supply Pressure: 6-7.5 bar (90-110 psi)
• Air Inlet Pipe Diameter: 3/8 inch
• If there is no external air source, use a small compressor

Water Requirements:

• Tap Water Supply: Hardness should not exceed 0.7-2 mmol/l
• Tap Water Pressure: 4-6 bar (50-80 psi)
• Feed Water Pipe Diameter: 1/2 inch

Drain Requirements:

Connect the following outlets directly to a drain funnel or connect them through a drain collector pipe of 2 inches diameter that should be covered. The drain system should be vented. Connect the system drain by 3/4 inch diameter pipe.

Configuration:

• Chamber Dimensions (WxHxD) (mm): 20 in x 20 in x 38 in (510 mm x 510 mm x 970 mm)
• Chamber Volume (Liter): 250
• External Dimensions (WxHxD): 44 in x 75 in x 56 in (1120 mm x 1910 mm x 1430 mm)
• Input Voltage: 115 VAC

Thermo / Lab-Line / Barnstead C57835 Autoclave / Sterilizer
This Barnstead Thermolyne Benchtop Autoclave / Sterilizer C57835 is used, and in excellent condition. It is similar to the Barnstead GLS-10D Autoclave / Sterilizer. Printer is missing paper.
Ajax Loader

Loading Next...

Contact Us
Fax:

(240) 376-1381