Items/Page
Showing 1-100 of 159 Results
This Perkin Elmer NCI-902 Network Chromatography Interface is used, and in good condition. It is the Dual Analog Channel version of the NCI series instruments. No software included. This unit is missing bottom supports for vertical standing orientation.

The NCI-902 is analogous to a model 970A.

Relay Module is not installed on this unit.

View Photo of missing bottom supports.

This Perkin Elmer NCI-902 Network Chromatography Interface is used, and in excellent condition. It is the Dual Analog Channel version of the NCI series instruments. No software included.

The NCI-902 is analogous to a model 970A.

Relay Module is not installed on this unit.

This Perkin Elmer NCI-901 Network Chromatography Interface is used, and in excellent condition. It is the Single Analog Channel version of the NCI series instruments. No software included.

The NCI-901 is analogous to a model 941A.

This Gilson 305 HPLC Piston Pump is used and in excellent condition. This unit ships with a 200WTi, titanium pump head.

200WTi
Configuration:

• Flow Rate: 1.000 mL/min - 200 mL/min
• Pressure Range: 72.5 - 508 psi (5 - 35 bar)

This Perkin Elmer 970 Network Chromatography Interface is used, and in excellent condition.

The 970 has Channel A & B differential inputs and a GPIB connection.
This Jasco LC Net II / ADC Chromatography Data Solutions is used and in excellent condition.

The LC-NetII/ADC is the hardware interface between your PC and the system components.


Configuration
• Jasco HPLC/ADC Software Disk: ChromoConver Ver 1.0 and SpectraManager Ver 1.40
• LC-Net Connection Cable: approximate length 5 feet

This Thermo SpectraSYSTEM P4000 Quaternary Gradient Pump is used and in excellent condition. This unit does not include any consumables or accessories.
This PE Nelson 610 Link Unit is used and in excellent condition.

The Model 610 LINK Interface, includes 1MB RAM.
Configuration
• Width: 19 Inches
• Height: 13.5 Inches
• Depth: 14.5 Inches
This Waters Millennium 32 Chromotography Manager Software is used and in excellent condition. Software sold by Artisan does not included a warranty and therefore cannot be returned.

The
box contains:
• (2) Software CD's
• (2) Interactive Tutorial CD's
• System Installation / Configuration Guide
• Data Acquisition / Processing Theory Guide
• Read Me First Booklet
• Getting Started Guide
• Open Access Key Floppy Disks
• Original Software Documentation
• Workstation V3.2
• GPC Project

This Gilson 306 HPLC Pump is used and in excellent condition. This unit ships with a 10SC, stainless steel pump head.

10SC
Configuration:

• Flow Rate: 0.050 mL/min - 10 mL/min
• Pressure Range: 14.5 - 8700 psi (1 - 600 bar)

This BAS DA-5 Chromatography Control and Data System is used and in excellent condition.
This Thermo SpectraSYSTEM SN4000 System Controller is used and in excellent condition. This unit ships with a 100-240 V Adapter.

Part Number: 60053-60138
This TharSCF / Berger FCM-1200 Dual Pump HPLC Fluid Control Module is used, and in excellent condition.
This Bioanalytical Systems LC-3D Petit Amperometric Detector is used and in excellent condition. The LC-3D is powered via 9V Alkaline Battery or 12VDC external input. This unit includes the I OUT/ground to BNC connector and the cell lead cable. The AC adapter (center pin positive) is sold separately.
This Thermo / Dionex E01 Eluent Organizer is used and in excellent condition. This unit comes with two 2000 ml bottles.
This Bioanalytical Systems LC-22C Temperature Controller is used, and in excellent condition.
This Perkin Elmer 950A Network Chromatography Interface is used and in excellent condition.

The 950A has Channel A & B inputs and GPIB Connection.
This Waters 600E Multisolvent Delivery System is used and in excellent condition. This is the older version system. This unit comes the Waters 600 Fluid Unit and a standard rack.
This instrument was removed from service and a very good effort was made to keep all of its components and spares together. It will require some consumables, accessories and components as well as expertise in setting up such a system to become complete and ready to operate. We have documented the components and accessories that are included and not included with this instrument:

Accessories and Components Included:

• µSeparation Unit, µPrecision Pump, µPeak Monitor, µFraction Collector and System Power Supply are Included
• Included Tube Holder Capacity: 48 x 0.5 mL Sample Tubes and 4 x 24 mL Tubes
• 200 mL External Sample Loop Installed
• (4) Multinet Cables Included

Accessories and Components Not Included:

• OS/2 Operating System, SMART Manager and SMART Assistant Software are Sold Separately
• ISA/AT, Multinet, µControl Board Used for Interfacing to a PC is Sold Separately
• Various Consumable (i.e Bottles and Tubing)

This DX Series Chromatography System is used and in excellent condition. System includes LC20 Chromatography Enclosure, AD25 Absorbance Detector, CD25 Conductivity Detector, GP50 Gradient Pump, E01 Eluent Organizer, Dell computer, keyboard, and mouse.

PC Configuration:
• Windows 2000 OS
• Intel Pentium III 733Mhz Processor
• 128MB RAM
• 37GB HDD

Software Installed:
• PeakNet 6.40

CD25:
• Moduleware Rev 1.05
• Bios Rev 30.00
• DXLAN ID 0043DF

GP50:
• Pumphead Volume 100uL
• Moduleware Rev 3.51
• BIOS Rev 30.00
• DCLAN ID 004533

AD25:
• Moduleware Rev 1.09
• Bios Rev 31.06
• DXLAN ID AD0A94

View Photo of LC20 Chromatography Enclosure
View Photo of AD25 Absorbance Detector
View Photo of CD25 Conductivity Detector
View Photo of GP50 Gradient Pump
View Photo of E01 Eluent Organizer

This Agilent / HP 5890 Series II Gas Chromatograph is used and in excellent condition. This Gas Chromatograph was pulled from a working lab environment. We do not have the expertise to fully test this unit and have documented all the information gathered from it in this page. It is recommended that the purchaser of this system contact Manufacturer for installation, setup and maintenance. A very good effort was made to retain accessories. The PC is sold separately.

Configuration:

• Single Packed Column Injector
• Single Flame Ionization Detector (FID)
• 19095J-123 HP-5, 30 m, 0.53 mm, 2.65 μm Column Installed
• 7673 Automatic Sampler System Installed
• Communication PCB Installed

Accessories Included:

• 19095-60610 5 m, 530 um, Deactivated Retention Gap Column
• Cables
• HP 3365 Series II ChemStation Software for Windows 3.1
• 18594-69060 Board
• (7) New 5062-3512 85/15 Vespel/Graphite 0.74 mm Ferrule
• (23) New Restek Termolite 27141 11 mm Septa
• (4) 5181-8836 Column Cutter
• 19231-60680 Spare Igniter
• (3) Chromatography Research Supplies Gas-Dry Filter Trap


View Photo of the injector.
View Photo of the detector.
View Photo of the columns.
View Photo of the Gas-Dry Filter Traps.
View Photo of the cables.
View Photo of the manuals and software.
View Photo of the 18594-69060 Board.
View Photo of the other accessories.

This Harvard Apparatus TC-202A BiPolar Temperature Controller is used and in excellent condition.
This Agilent / HP 6890A Gas Chromatography System is used and in excellent condition. We do not have the expertise, accessories or software to fully test this unit and have documented all the information gathered from it in this page. This item will be sold as/is without warranty and will be priced accordingly. Additional photos available on request.

Columns, carrier gasses, and other accessories sold separately. It is recommended that the purchaser of this system contact Manufacturer for pricing and availability of all accessory that may be necessary for your application.

Configuration:
• (1) Split/Splitless Injectors
• (1) EPC Pneumatic Modules

View Photo of the top of the system.
View Photo of the Detector site.
View Photo of the Injector.
View Photo of the EPC module.
View Photo of the exposed back of the system.
View Photo of the exposed right side of the system.
View Photo of the exposed left side of the system.

This PE Nelson 600 Link Unit is used and in excellent condition.

The Model 600 LINK Interface, includes 256KB RAM.
This Perkin Elmer 970A Network Chromatography Interface is used, and in excellent condition.

The 970A has Channel A & B differential inputs with Ground and a GPIB connection.
This Beckman Coutler 168 Programmable Diode Array Detector Module is used and in excellent condition.The UV D2 lamp is used and has unknown remaining life.

Configuration

• UV D2 Lamp: 190-360 nm
• Input Voltage: 120V

Cables:
• 25-Pin D-SUB (Male) to 5-Pin DIN (Male) and 5-Pin DIN (Female)
• PS/2 Cable
• 15-Pin D-SUB to RS-232 Cable

This Agilent / Varian Saturn 2000 Gas Chromatograph / Mass Spectrometer is used and in excellent condition. This unit does not include the Data System.

CP-3800 Gas Chromatograph
Configuration:
• Injector Option: CP-1177 Split / Splitless
        Pressure Range: 0-100 psi
        Total Flow: 500mL/min at 10 psi
        Maximum Temperature: 450°C
        Split Range: 1-10,000 (Column Dependent)
• Detector Option: None Installed
• Software: Chrompack Version 3.3.5d
• Automation Option: CP-8400 AutoSampler
        Sample Capacity: 100 x 2 mL vials
        Dual and Duplicate Mode
        Internal Standard Addition
• Display: LCD Display 11 lines, 35 characters/line
• Input Voltage: 120 VAC

Saturn 2000 Mass Spectrometer Configuration:
• Ionization Mode: Electron Ionization Standard
• Mass Range: 10 to 650μ (Programmable Scan Range Time)
• Full Spectrum Scan Rate: Up to 10 Hz (Depends on Mass Range selected)

DS 102 Rotary Vane Vacuum Pump Configuration:
• Free Air Displacement: 95 l/min(5.7m3/h) at 50 Hz, 114 l/min(4 cfm) at 60 Hz
• Pumping Speed: 5m3/h at 50 Hz, 3.5 cfm at 60 Hz

Parts and Accessories Included:
• (1) ETP AF147 Active Film Multiplier (PN: 14147)
• (2) Rainin Presterilized Filters
• (1) Varian CP22311 Tubing Teflon 1/8” x 1.5 mm
• (1) Varian CP4631 Vespel Ferrule 1/16” x 0.5mm
• (1) Varian CP4621 Vespel Ferrule 1/16” No Hole
• (8) Viton Ferrule, Disc. Use-50 (PN: 03-917142-00)
• (8) Washer Ferrule, Hold Use-50 (PN: 03-917157-00)
• (1) Ferrule, Comp. Ftg. Front (PN: 28-694027-00)
• (1) Ferrule, Comp. Ftg. Back (PN: 28-694028-00)
• (17) Capillary Inj. Nut Assembly, Brass Capillary (03-949551-00)
• (7) Agilent 10ul Manual Syringe (PN: 5190-1483)
• (1) Varian 392521701 Bakeout Nut, 1177
• (1) Varian 392573101 Disk, Purge, CP-1177
• (3) Agilent Filament Disk Assembly with Wires, Saturn 2000 (PN: 393060191)
• (9) Varian CR213104 1/16” to 0.425mm V/G Ferrule (10 Per Pack)
• (1) Washer, Spring, Wavy, 0.75 OD, 0.50 ID (PN: 14-92009-00)
• (1) Varian Extraction Tool (PN: 7200008400)
• (1) Spacer Saturn to GC (PN: 03-930613-01)
• (2) Spring Gold Plated, Trap (PN: 03-930605-01)
• (1) 3800 Contact Removal Tool for Heaters (PN: 29-899614-00)
• (1) 3800 Contact Removal Tool for Temperature Probe (PN: 03-909196-00)
• (6) Hillman Hex Cap Screw Class 8.8
• (1) Varian CR298713 Coated 9mm BTO Center Guide (50 Per Pack) (ID: 282350)
• (2) Fuse, 10 A Type F, 3800 (PN: 55-500348-00)
• (2) Fuse, 6.3A Type T
• (2) Turbo Pumps Instruction Manual (Disk)
• (1) Rotary Vane Pumps HeliTest & Pumping Systems Instruction Manual (Disk)

Click here to view a photo of the parts and accessories.
Click here to view a photo of cables included.

The Gilson 100326 is the UV lamp assembly for the 155/156 Series Detectors. This assembly is new from surplus stock (it was a back-up/standby unit). The hour meter is at zero, and the physical condition of the unit indicates it has never been installed in anything.
This Perkin Elmer NCI-901 Network Chromatography Interface is new from surplus stock. It is the Single Analog Channel version of the NCI series instruments. It comes with NCI Accessories, which include power cable, terminal blocks and manual. No software included.

The NCI-901 is analogous to a model 941A.

This Newport 350B Thermoelectric Cooler Controller is used and in excellent condition.
This unit has a 5SC, stainless steel pump head with a flow rate of 0.01 mL/min - 5 mL/min.
This unit has a 10SC, stainless steel pump head with a flow rate of 0.05 mL/min - 10 mL/min.
This Agilent / HP 6890A Gas Chromatography System is used and in excellent condition. We do not have the expertise, accessories or software to fully test this unit and have documented all the information gathered from it in this page. This item will be sold as/is without warranty and will be priced accordingly. This unit is missing the top cover, which should have no effect on functionality. Additional photos available on request.

Columns, carrier gasses, and other accessories sold separately. It is recommended that the purchaser of this system contact Manufacturer for pricing and availability of all accessory that may be necessary for your application.

Configuration:
• (2) Split/Splitless Injectors
• (2) EPC Pneumatic Modules
• (1) Flame Ionization Detector
• (2) Flame Ionization Detector Manifold Assemblies

View Photo of the top of the system.
View Photo of the Detector.
View Photo of the Injectors.
View Photo of the EPC modules.
View Photo of the exposed back of the system.
View Photo of the exposed right side of the system.
View Photo of the exposed left side of the system.

This KNAUER WellChrom K-2600 UV Detector is used and in excellent condition.
This Michrom Magic 2002 HPLC instrument is used, and in excellent condition. It includes the Michrom 718/P Autoinjector. The system ships as shown with instrument, autoinjector, interconnection cables, computer, software (EZ Chrom Elite, Magic V1.1), dongle, keyboard, and mouse (just add your own pc-standard monitor). Our technicians have checked the functionality of this instrument including the autoinjector armature movement and syringe operation, computer-controlled operation of the instrument including the lamps, detector, gradient pumps, and injection valve. The UV D2 lamp has only about 25% of use shown on its indicator strip. Small consumable accessories are not included such as columns. Michrom offers reasonable service contracts for the Magic 2002 (Full- & Self-Service plans). Their website currently lists pricing for consumables, accessories, and replacement costs for 'wear' components for this instrument.
This Agilent / Polymer Laboratories PL-EMD 960 Evaporative Light Scattering Detector is used and in excellent condition.
This Bioanalytical Systems CC-5E Liquid Chromatography Flowcell Compartment is used and in excellent condition.

BAS Epsilon Series Analyzer Installed

Rheodyne 7125 Manual Sample Injector

Model Number: CC-5E

This Bioanalytical Systems CC-5 Liquid Chromatography Flowcell Compartment is used and in excellent condition.

BAS LC-23B/LC-23C Column Heater Installed

BAS LC-22C Preheater Installed
Rheodyne 7125 Manual Sample Injector

This Beckman Coulter 166 Programmable UV/VIS Detector Module is used and in excellent condition. The UV D2 lamp is used and has unknown remaining life.

Configuration
• Input Voltage: 120V
This Bioanalytical Systems MF-6213 Analytical Column is new from surplus stock. This unit ships in manufacturers box.

The MF-6213 is a 3um PHASE-II ODS analytical column for supported liquid chromatography (LC) systems.

This Beckman Coutler 168 Programmable Diode Array Detector Module is used and in excellent condition. The UV D2 lamp is used and has unknown remaining life. This unit ships with a platform tray.

Configuration
• UV D2 Lamp: 190-600 nm
• Input Voltage: 120V


Configuration:
• H2 Flow Rate/Capacity: 0 to 160 ml/min

Input Voltage: 110-120 VAC / 230 VAC

Part Numbers: PG-H160, N9306059

This Agilent / HP 5890 Series II Gas Chromatograph is a parts unit being sold as-is. This unit is incomplete and is missing the detector, column, panels, and other components. It will be sold as-is without warranty and will be priced accordingly. If you would like to purchase an individual component of this unit, please contact Artisan Technology Group Sales for pricing and availability. The photos of this item are representative. The units sold may not be identical to those pictured.

View Photo of the inside of the side panel.
View Photo of the missing detector.
View Photo of the side of the unit with the panel removed.
View Photo of the rear of the unit with the panel removed.

Part Numbers: 05890-60015C, 1927-60010, 300306

This Gilson 811D Dynamic Mixer is used and in excellent condition.

Configuration:

• 23 mL Pump
• 110/220 V
This Waters 486 Tunable Absorbance Detector is used and in excellent condition.
This Bioanalytical Systems CC-5 Liquid Chromatography Flowcell Compartment is used and in excellent condition.

BAS LC-23B/LC-23C Column Heater Installed
This Bioanalytical Systems CC-5 Liquid Chromatography Flowcell Compartment is used and in excellent condition.

BAS LC-23B/LC-23C Column Heater Installed

BAS LC-22C Preheater Installed

This Bio-Rad 125-0425 HPLC Column Heater is used and in excellent condition. This unit includes (2) 1/4 inch column inserts. Other column inserts are sold separately.

Part Number (Catalog Number): 125-0425

This Bio-Rad DCode Universal Mutation Detection System is used and in excellent condition. This unit does not include the basin. This unit has been priced accordingly.

Input Voltage: 120 VAC only.
This unit is missing the front panel cover. However this does not affect its functionality in anyway.

Part Number: 728747
This Thermo SpectraSYSTEM UV2000 Dual-wavelength Detector is used and in good condition. The front panel is missing; however, this does not affect the functionality. This unit does not include any consumables or accessories.
This Amersham (GE Healthcare) SuperDex 75 Prep Column is new from surplus stock. It ships in the original packaging. It comes with the instruction sheet and XK-16 Accessory Kit (56-0011-61). The column is labeled:

XK 16
HiLoad 16/60
Superdex 75
Prep Grade
Part Number: 17-1068-01

More information can be found on the Amersham/GE website.

This TharSFC / Berger SFC Thermal Control Module is used, and in excellent condition.

Model: TCM-2000
S/N: 9709T001
Power: 120 VAC

Options: Manual Injection Valve w/10ul sample loop

This Thermo / Dionex CD25 Conductivity Detector is used and in excellent condition.

Configuration:
• Moduleware Rev: 1.05
• Bios Rev: 30.00

• DXLAN ID: 0043DF


Accessories and Components Included:

• µSeparation Unit, µPrecision Pump, µPeak Monitor, µFraction Collector and System Power Supply are Included
• Included Tube Holder Capacity: 41 x 1.5 mL Sample Tubes
• 20 µL External Sample Loop Installed
• (4) Multinet Cables Included
• Compaq Deskpro EN Series, Intel Pentium III 500 MHz, 64 MB Memory
• OS/2 Operating System and SMART Manager Software
• ISA/AT, Multinet, µControl Board

Accessories and Components Not Included:

• SMART Assistant Software
• Various Consumable (i.e Bottles and Tubing) and DB15 Male to DB9 Female Cable

This Millipore / Amicon Vantage-S Chromatography Column is used and in good condition. This item ships as pictured with no other accessories or documentation.
This Gilson 322 HPLC Pump is used and in excellent condition. This unit includes a Gilson 506C System Interface Module and two plastic trays, as seen in the photograph.

Configuration:

• (2) H2M Pump Heads Installed
• Flow Rate: 0.15 to 15 mL/min, Adjustable in mL/min

This Matec Applied Sciences CHDF 2000 - Capillary Hydrodynamic Fractionation is used and in excellent condition. This unit has been tested and verified to be working. However, the Fractionation Cartridge needs to be replaced and the pH probe is not included. Please contact Matec for pricing and availability of the parts.

Configuration:
• Windows 95
• 32 MB RAM
• 2.37 GB HDD
• CHDF2000 Software Version 2.73

Accessories Included:
• Fractionation Cartridge (needs to be replaced)
• (1) Micromeritics Instruments penetrometer stem (Part Number 920-61713-01)
• Cables
• Manual
View Photo of penetrometer stem and cables
View Photo of pH probe assembly

This EG&G Princeton Applied Research 400 Electrochemical Detector is used and in excellent condition. Liquid Chromatography Cell included. Option 99 installed.
This Thermo / Dionex GP50 Gradient Pump is used and in excellent condition.

Configuration:
• Pumphead Volume: 100uL
• Moduleware Rev: 3.51

• BIOS Rev: 30.00
• DCLAN ID: 004533

Usage Data:
• Module On: 4135 hrs
• Backlight: 210 hrs
• Pump Cycles: 130618 cycles

This Beckman Coulter 166 Programmable UV/VIS Detector Module is used and in excellent condition. The UV D2 lamp is used and has unknown remaining life.

Configuration

• UV D2 Lamp: 190-360 nm
• Input Voltage: 120V

This Agilent / HP HP1 GC Capillary Column is new from surplus stock.

Part Number: 19095Z-123E

Configuration:
• Film Thickness: 2.65um

• Length: 30m
• Phase Ratio: 50
• Column ID: 0.53nm

This Newport 350 Thermoelectric Cooler Controller is used and in excellent condition.
This Grace Davison / Alltech C-5000 Capillary Column is used and in excellent condition. It is 10 feet long and 1/8 inch in diameter.
This Perkin Elmer Series 200 HPLC Pump is used, and in excellent condition. Software not included.
This Gilson VALVEMATE Valve Actuator is new from surplus stock. This unit has the Hamilton 86918 HVXD 8-5 Low Pressure Valve installed. This unit ships in the original manufacturer's box with US and European power cords. Additional cables and fitting sold separately.
This Matec Applied Sciences CHDF 2000 - Capillary Hydrodynamic Fractionation is used and in excellent condition. This unit has been tested and verified to be working. However, the Fractionation Cartridge may need to be replaced and the pH probe is not included. Please contact Matec for pricing and availability of the parts.

This unit is missing a flat panel inside which covers the right side of the unit and keeps the door closed. View Photo of the inside of the unit.

Configuration:

• Revision 4.2
• Column Heater Installed
• Chamber Size: 25µL
• Windows XP SP2
• 512 MB RAM
• 37 GB HDD
• 1.8GHz Pentium 4 Processor
• CHDF2000 Software Version 3.20 (32 bit)

Accessories Included:

• Fractionation Cartridge (model G204; might need to be replaced)
• PC Tower
• CRT Monitor
• Keyboard and Mouse
• Monitor Power Cable
• Connection Cables for Monitor to PC and to CHDF
• Manual

This Waters 600E Multisolvent Delivery System is used and in excellent condition. Included: 600 Graident Controller, Waters 600E Pump, 37-pin DB Connector Cable, and optional Rheodyne® 7725i Variable-Volume, Syringe-Loading Sample Injector.
This Bioanalytical Systems LC-3D Petit Amperometric Detector is used and in excellent condition. The LC-3D is powered via 9V Alkaline Battery or 12VDC external input. The AC adapter (center pin positive) is sold separately.
This TharSFC / Berger SFC Thermal Control Module is used, and in excellent condition. Unit is fully functinal, but is missing (2) of the panels at the top-front of the unit (as seen in photo). Fused for 120VAC only.
This Thermedics Detection EZ Flash High-Speed Gas Chromatography System is used and in excellent condition.

Part Number: C412400000
This Thermo / Dionex LC20 Chromatography Enclosure with Computer is used and in excellent condition.

PC Configuration:
• Windows 2000 OS

• Intel Pentium III 733Mhz Processor
• 128MB RAM
• 37GB HDD

Software Installed:
• PeakNet 6.40

The software listed above is loaded onto the system and does not include the CD media. This system's hardware and software configuration is preserved as it was originally used. It will be the end user's responsibility to comply with any non-transferable software licensing issues and delete any software that is deemed non-transferable. Upon request, we can delete and format the hard drive prior to shipping for a $20.

This is the main box only. No external accessories are included.

Part Number: 1-292-01
This Tosoh Bioscience TSKgel G5000PWXL Column is used and in excellent condition.

Configuration

• Dimensions: 7.8 mm X 30 cm
• Particle Size: 10 µ
• Standard Flow Rate: 0.3 - 0.6 mL/min
• Max. Flow Rate: 1.0 mL/min
• Max. Pressure: 300 psi
• Temperature Range: 10-80ºC

This Gilson 807 Manometric Module is used and in good condition. This unit connects to the 305 through the rear connector. The pump head is sold separately.

Configuration:

• Maximum Pressure: 8 MPa

This Lumasense Technologies / Luxtron 0221 1015 Series Monochromator is new from surplus stock. The unit ships with an RS-232 cable.
This Gilson VALVEMATE Valve Actuator is used and in excellent condition. This unit has the Rheodyne 7000 2-Position, 6-Port, High-Pressure Valve installed.
This Bioanalytical Systems LC-4B Amperometric Detector is used and in excellent condition.
This Gilson 156 UV/VIS HPLC Detector is used, and in excellent condition. It requires Gilson software (not included in sale) such as Unipoint to operate. If you do not already have a version of Unipoint, it can be purchased through Gilson directly.

Gilson 156 w/0.2mm Preparative Flow Cell

This unit includes a load/inject lever and a 5 µL capillary tube.

Part Number: WAT055840
This unit does not included the AC adapter nor the terminal blocks. Please contact manufacturer for pricing and availability.

Part Number: WAT200341
This unit does not have the needle of the needle wash pump.

Configuration:
• Sample Capacities/Carousel: 48 Samples with 4 mL Capacity

• Optional Heating/Cooling Module: Installed
• Input Voltage: 110/120/220/240 VAC
• Dimensions: 15 x 16 x 21 inches

View Photo of missing needle.

Part Number - WAT078900

This EG&G Princeton Applied Research 400 Electrochemical Detector is used and in excellent condition. Liquid Chromatography Cell included.

Here is a photo of the Liquid Chromatography Cell:
Liquid Chromatography Cell

This Waters 600S Controller is used and in excellent condition.

Part Number: WAT055727
This Thermo / Dionex 4500 ml DX Series Chromatography System Bottle is used and in excellent condition.
This Perkin Elmer 941A Network Chromatography Interface is used and in excellent condition.

The 941 has Channel A & B inputs and RS-232 Serial Communication Port.
This Perkin Elmer 941A Network Chromatography Interface is used and in excellent condition.

The 941A has Channel A & B inputs and includes an FAX752 adapter.
This HP / Agilent 79853C VWD is used, and in excellent condition. This is the latest 1050 VWD 79853C model system with the Enhanced Optical Unit ("D") installed. The newer optical unit has improved performance over the previous versions. This unit also has the Ultra High Pressure Cell (400 bar) interface.
This Gilson 200WTi Piston Pump Head is used and in excellent condition.
This unit has vertical lines in the LCD display; however, this does not affect its ability to function properly.

Configuration:

• Sample Capacities/Carousel: 48 Samples with 4 mL Capacity
• Optional Heating/Cooling Module: Installed
• Input Voltage: 110/120/220/240 VAC
• Dimensions: 15 x 16 x 21 inches

View Photo of display.

Part Number - WAT078900

This unit has a 00S-0054L Cheminert fitting attached.
Configuration:
• Particle Size: 5 µm
• Phases: C4, 250 x 4.6 mm
This Tosoh Bioscience TSKgel G2500PWXL Column is used and in excellent condition.

Configuration

• Dimensions: 7.8 mm X 30 cm
• Particle Size: 6 µ
• Standard Flow Rate: 0.5 - 0.8 mL/min
• Max. Flow Rate: 1.0 mL/min
• Max. Pressure: 600 psi
• Temperature Range: 10-80ºC

This Tosoh Bioscience TSK-Gel G3000PWXL Column is used and in excellent condition.

Configuration

• Dimensions: 7.8 mm X 30 cm
• Particle Size: 6 µ
• Standard Flow Rate: 0.5 - 0.8 mL/min
• Max. Flow Rate: 1.0 mL/min
• Max. Pressure: 600 psi
• Temperature Range: 10-80ºC

Part Number: 08021

This Perkin Elmer Series 200 Diode Array Detector is used and in excellent condition. The deuterium lamp's hour meter shows ~120 hours used out of 1000 hours. The front panel is included, no software included.
This Bioanalytical Systems PM 60 HPLC Pump is used and in excellent condition.
This Bioanalytical Systems PM-80 Solvent Delivery System is used and in excellent condition. This unit does not have a pump installed.
Showing 1-100 of 159 Results
Contact Us
Fax:

(240) 376-1381