Items/Page
Showing 1-100 of 476 Results
Configuration:
• Capacity: 450μl
• Non-Sterile
• 480 Tips
This Thermo / Forma Scientific Gas Guard Model 3050 is used and in excellent condition.
This Agilent Genomics / Stratagene Stratalinker 2400 UV Crosslinker is used and in excellent condition.

Input Voltage: 120 VAC
This Atlas Suntest CPS+ Xenon Test Instrument is used and in excellent condition. Software and cables are not included. Please contact manufacturer for pricing and availability.

Input Voltage: 200 to 240V
Software and cables are not included. Please contact manufacturer for pricing and availability.

Lead time could take up to 4 - 8 weeks.
All Sales are final


Input Voltage: 200 to 240V

This Atlas Suntest CPS+ Xenon Test Instrument is used and in excellent condition. This unit includes the optional SunCool Chiller to reduce test chamber temperature.

Input Voltage:
200 to 240V

Includes SunCool Chiller Configuration:

• Optional SunCool Condenser Unit
• Optional SunCool Evaporator Unit
• Refrigerant: R407c

If you would like to purchase the units separately please contact an Artisan Sales Associate for pricing and availability.

This item ships as pictured, without any additional cabling or external sensors.

Configuration:
• All Analog Inputs are 4 - 20 mA
This Bio-Rad EM-1 Econo UV Monitor is used and in excellent condition. The optics module, cables and fittings are not included.
This Lumasense Technoloies / Luxtron STS-2 Fluoroptic Thermometer Probe Kit is new from surplus stock. This unit includes standard documentation.

Configuration:
• Application: Surface Contact
• Temperature Range: -25 to 200°C
• Response Time: 25 milliseconds

Kit Includes:
• (2) 10cm Replaceable Tips
• (1) 2m Probe

Part Number: 00-13738-02

This Malvern Bohlin Gemini HR Nano Rheometer is used and in excellent condition. Unit requires dry air to operate.

Configurations:

• (2) Plastic Containers with Pumps
• (2) Female to Female 9-Pin Cables: Part Number 09465
• (1) Female to Female 9-Pin Low Voltage Computer Cable
• (1) CD of Bohlin Rotational Rheometry Software

Screen Shot Photos Taken During Technician Test:
View Photo of Viscometry Run on Water.
View Photo of Viscometry Run on Milk.

This Thermo / Forma Scientific Gas Guard 3030 is used and in excellent condition.

Configuration:

• Long Length Version
AS-200 Configuration:
• System A / B Low Cylinder
• System A / B Pneumatic Outlet
• Pneumatic Supply

• Pneumatic Exhaust

Input Voltage: 120/240VAC

This Gilson Pipetman P20 Single Channel Pipette is used and in excellent condition.

Volume: 2 to 20 µL
This Bio-Rad 583 Gel Dryer is used and in excellent condition.

Input Voltage: 120V

Part Number: 165-1745
This Eagle Stainless Container CTH-30 Stainless Steel Container is used and in excellent condition.

Configuration:

• Nominal Volume: 5.3 US Gal. (20.0 l)
• Actual Volume: 5.8 US Gal. (21.8 l)
• Inner Diameter: 11.81 in. (300 mm)
• Height: 11.81 in. (300 mm)
• Thickness: 0.8 mm
• Weight: 7.1 lb (3.2 kg)
• Alloy: T-316L SS

This Thermo / HAAKE RS100 Control Unit is used and in excellent condition.

Part Number (Typ): 002-4008

Back Connectors:

• I: Connects Main Cable to RS100
• II: Receives Measurement Single From RS100
• III: RS232 Interface Connection
• IV: Additional RS232 Interface for Additional External Devices
• VI: Control Socket for Liquid Temperature Control
• External Analog Control: Temperature Sensor Control for an External Device
• PT100: Additional External Temperature Sensor Connection
• External Voltage Input: 0-10V Input for External Device Measurement Signals

View Photo of the back of this unit.

This Thermo / Forma Scientific Gas Guard 3030 is used and in excellent condition.

Configuration:

• Short Length Version
This Thermo / Pierce Reacti-Therm III Heating Module is used and in excellent condition. This unit comes with 1 block inserted and the Reacti-Vap III 18785 top unit with 27 (out of a possible maximum of 27) insertion tubes installed.

Model: 18835

Included Reacti-Block Aluminum Blocks:
• (1) Q-1, Holds 10 mL Reacti-Vial Small Reaction Vials, 8 Holes (26 dia. x 46 mm deep)

Input Voltage: 120 VAC Only

This PTI D-104 Dual-Channel Microscope Photometer is used and in excellent condition.

Configuration:

• (1) 01-710 P.M.T. Housing Installed
• (1) 814 Photomultiplier Detection System Installed
• (1) Olympus Objective, CWHK 10X/18L

If one component of this unit is desired, please contact Artisan Technology Group sales for pricing and availability.

This Mettler Electronics Sonicator 706 Ultrasound Machine is used and in good condition. The top of the case on this unit has been cracked however this does not affect the functionality.

Disclaimer: This unit is being sold as an inspection tool for use in troubleshooting electronic equipment and not for use on human and/or animal subjects and should be handled and used only by a qualified person familiar with its use.

Configuration:
• Input: 120VAC, 60Hz
• Frequency: 1.0 MHz ±5%
• Pulse Repetition Rate: 100 Hz ±20% (PULSE MODE)
• Pulse Duration: 2 msec ±20% (PULSE MODE)
• Temporal Peak / Average Intensity Ratio: 5 ±20%
• Beam Type: Collimating

View Photo of cracked case.

This Gilson Pipetman P1000 Single Channel Pipette is used and in excellent condition.

Volume: 200 to 1000 µL
This Thermo / Forma Scientific Gas Guard Model 3050 is new from surplus stock. Standard accessories and documentation included.

We often have stock of this equipment. Please call for availability.

This Gilson Pipetman P200 Single Channel Pipette is used and in excellent condition.

Volume: 50 to 200 µL
This Allentown Exhaust-PAK EP5000E Micro-VENT Blower System is used and in excellent condition. This unit has been designed to provide reliable, trouble-free performance on the positive flow Micro-Vent IVC systems.

Input: 100-120 VAC, 50/60 Hz

This Peak Scientific NM20ZA Nitrogen Generator is used and in excellent condition.

Input Voltage: 230 V
Input Current: 5 A
Input Frequency: 50/60 Hz


Dimensions: 23" W X 26.5" D X 34.5" H (60.95 cm X 70.225 cm X 91.425 cm)

Included:
• Standard Knife Carrier
• Disposable Blade Carrier E

• Quick Release Clamp

Part Number: HM 355 S
Catalog Number: 905480

Input Voltage: 115 VAC Only

Configuration:
• 12-Channel

• 20µL to 200 µL

Corning Costar 12-Pette Manual (pdf)

This Pace Arm Evac 250 Fume Extractor is used and in excellent condition.

Input Voltage: 110 V
Model Number: 8889-0255
This TSI / Alnor Airgard Model 350-CEM Air Flow Monitor is used and in excellent condition.

AC Adapter Input Voltage: 120 VAC Only
This Agilent Genomics / Stratagene Stratalinker 2400 UV Crosslinker is a parts grade unit and is being sold as-is, without warranty and will be priced accordingly. If you would like to purchase an individual component of this unit, please contact Artisan Technology Group Sales for pricing and availability. This unit has a cracked housing and front panel.

Input Voltage: 120 VAC

View Photo of cracked housing unit.
View Photo of cracked front panel.

This Parr Instrument 4635 Cell Disruption Vessel is used and in excellent condition.

Configuration
• Internal Volume: 920 mL

• Maximum Sample Size: 600 mL
• Maximum Working Pressure: 2200 psig
• Inside Diameter: 3.75"
• Inside Depth: 5.10"

Parts Included by Part Number:
• 583HCPG: Pressure Gauge, 3.5", 3000 psi
• A888HC
• Two A122VB: Needle Valve: 1/8" NTP, Male
• Two 260HC2: Valve Extension
• 441HC: O-Ring, Neoprene
• 599HC21: Bomb Cylinder, 920mL, T316SS
• 591HC: Dip Tube with Nut, 920 mL
• A816HC: Split Ring, Pair
• A811HC: Drop Band
• 811HCF: Drop Band Bolt
• A121HWAD: Tube Connector
• 584HC: Discharge Tube

Includes:
• Cambridge AccuSense QuattroFlow Velocity Analyzer
• Cambridge AccuSense AirGrid

• (4) Cambridge AccuSense AG-100 Airflow & Air Temperature Sensor
• Hard Case for AirGrid
• Soft Case with shoulder strap for QuattroFlow
• AC Adaptor/Battery Charger for QuattroFlow
• Serial Cable

This is just the Electrolyzer main unit. No accessories or water bottles are included.
We have an assortment of polishing films available; please contact Artisan Technology Group Sales for pricing and availability.

Included Accessories:
• Hard Case
• Bench-Top Stand
• M4552.1 Protrusion Gauge
• (5) Resilient Surface Discs
• 4305.1 Four Position SC Holder
• 4304.1 Four Position ST Holder
• Tysonic Rechargeable SLA Battery w/ Case
• 4028.1 Battery Charging Adapter
• Power Adapter

Polisher Part Number: 9005.4
Protrusion Gauge Part Number: S09965, R18226

View Photo of included accessories.

Configuration:
• Zoom Status: WA (Wide Angle) and TP (Telephoto)
• Vertical Shift: 100% Up/Down

• Horizontal Shift (If Vertical Shift is 0%): 70% Left/Right
• Horizontal Shift (If Vertical Shift is 100%): 20% Left/Right

Included Accessories:
• Toraysee Lens Cleaning Cloth
• BFL Adjustment Tool

View Photo of Included Accessories.

Part Number: R9849975

This unit includes (4) spare 254 nm Stratagene bulbs.

Input Voltage: 120 VAC Only


View Photo of spare 254 nm Stratagene bulbs.

This Lumasense Technologies / Luxtron 790 Fluoroptic Thermometer is used and in excellent condition. Probes are not included.

Configuration:
• Option: 00-11490-01

Part Number: 72-11820-01

Included:
• Foot Pedal
• Standard Knife Carrier
• Disposable Blade Carrier E
• Extra Bottom of for Knife Carrier
• Waste Tray

• Quick Release Clamp

Part Number: HM 355 S -2
Catalog Number: 905130

Input Voltage: 115 VAC Only

This unit does not include a key, nor a fixture or fixture plate. Please contact manufacturer for pricing and availability.

Configuration:

• Dimensions: 13”W x 15”D x 6 1/2”H
• Power: 115V, 50/60Hz, 150Watt
• Display: LCD, 20 Character x 16 Line

This Weigh-Tronix WI-150 Ultra Low-Power Weight Indicator is used and in excellent condition. This unit comes with a 4-Pin to 2-Pin Cable (~8 ft / 2.4 m) and a 7-Pin Cable (~4 ft / 1.2 m).

View Photo of connectors on unit.

View Photo of 4-Pin to 2-Pin Cable.

View Photo of 7-Pin Cable.

This Bio-Rad EM-1 Econo UV Monitor is used and in excellent condition. This unit comes with the Optics Module Attachment. Cables and fittings are not included.
Staples are not included. As shown by the counts below, this unit has minimal use and is extremely clean.

Total Fold Count: 3150
Total Cutter Count: 250
This Thermo / Microm HM 325 Rotary Microtome is used and in excellent condition. The audible signal for when the unit reaches the set number of slices does not work. Contact Thermo for pricing and availability of this part and any other parts/accessories that are required for your application.

Dimensions (W x D x H) 420 mm x 490 mm x 280 mm

This unit has interior corrosion; however, this does not affect its ability to function properly.

Input Voltage: 120 VAC Only


View Photo of interior of unit.

This Eberbach Laboratory 8581 Blender Container is used and in excellent condition.

Measurements:

• Volume: 350 ml
• Total Height: 7.5 in
• Chalice Width: 3.25 in
• Base Width: 3.375 in

This Sigma Systems TP781 Thermal Platform with Controller is used and in excellent condition.

Configuration:
• Thermal Platform Model: TP781

• Dimensions: 11" X 11"
• Heating Wattage: 2700 Watts
• Coolant: Liquid Carbon Dioxide
• Controller: Model C4

C4 Controller Manual (pdf)

This VWR TW-26 w/ 8Watt White Light Transilluminator, UVP 115V is used and in excellent condition.
Configuration:
• 365nm UV

Included Accessories:

• Metal Case
• Three-Foot Extension Cord

Part Number: 97-0003-01

View Photo of included accessories.

This E. A. Fischione 1020 Plasma Cleaner is a lightly used demo unit. This unit is compatible with TEM specimen holders for FEI/Philips, Hitachi, JEOL, Zeiss/LEO, and Topcon.

Configuration:
• Cleaning gas: 25% Oxygen / 75% Argon
• Cleaning Pressure: 10 PSI
• Hour Meter: 3.0 hrs
• Dimensions: 20 x 20.5 x 22.3 in

View Photo of inside chamber.

View Photo of the hour meter.

This Gilson Pipetman P2 Single Channel Pipette is used and in good condition. This unit is missing the top cap of the pump.

Volume: 0.2 to 2 µL


View Photo of the missing cap.

This Bio-Rad / MJ Research PTC-100 Programmable Thermal Controller is used and in excellent condition.

Configuration:
• Model Type: Hot Bonnet with 96-Well Block

• Thermal Range: 0-100°C
• Accuracy: ±0.5°C
• Number of Wells: 96
• Ramping Rate: Up To 1.2°C/sec
• Sample Capacity: 96 x 0.2ml tubes or one 96-well plate
• Line Voltage: 100-240 VAC
• Display: One 2 x 16 LCD alphanumeric display
• Ports: One 25-pin 8-bit parallel interface printer port

This WAB KDL-A Dyno-Mill Bead Mill is used and in excellent condition.

Configuration:
• Operating Voltage: 3 X 415 V, 50 Hz

• Nominal Capacity: 1.85 kW
• Nominal Current: 3.55 A
• View Photos of Included Accessories Here and Here

This Bruker API 1600 ESI / APCI Control Unit is used and in excellent condition.
This Thermo / Barnstead A56210-857 Fi-Streem III Glass Still Single Distiller is used and in excellent condition. All items and accessories included are shown in the photos.

Configurations:
• Model: A56210-857
• Input Voltage: 240 VAC
• Dimensions W x D x H: 12 x 15 x 30 in
• Cooling Water Consumption: 60 LPH
• Water Capacity: 4 LPH
• Number of Heaters: 2

Barnstead A56210-857 Fi-Streem III Glass Still with door removed View Photo


This Bego Triton SLA Wet and Dry Steam Cleaner is used and in excellent condition.
This Chapman VSE 3000 Volume Static Eliminator is used and in excellent condition. This product is manufactured by SIMCO.

Part Number: 1073501

Configuration:

• Input: 115V, 60 Hz, UL listed
• Discharge Time: <1.0 sec (1000 V to 100 V) at 12”
• Size: 12” W X 6.25” H x 10” D
• Weight: 8 Ibs. (3.6 kg.)
• Air Volume Output: 80 to 160 cubic ft/min (38 to 76 liters/sec)
• Air Velocity: 550 ft/min at 2 ft at max fan speed (2.8 m/sec at 0.6 m)

The Thermo / Pierce Reacti-Therm III Heating/Stirring Module Triple-Block is used and in excellent condition. It comes with 3 blocks inserted and the Reacti-Vap III 18785 top unit with 9 (out of a possible maximum of 27) insertion tubes installed.

Model: 18935

Included Reacti-Block Aluminum Blocks:
• (2) B-1, Holds 3 or 5 mL Reacti-Vials Small Reaction Vials, 9 Holes (21 dia. x 32 mm deep)
• (1) T-1, Holds 16 mm dia. Test Tubes, 9 Holes (17 dia. x 45 mm deep)

Input Voltage: 120 VAC Only

This Ericsson / Amherst 135-TRSKW Fiber Optic Heat Stripper is used and in excellent condition. This unit does not include the power supply.

This Thermo / Haake Viscotester 6R Plus Rotational Viscometer is excellent, like-new condition. It has been used very little. The unit includes the basic instrument with stand, spindles R2 to R7, rack, and spindle guard in a protective case.

6R Plus:
• Manufacture Number: 388-0100
• Accuracy: ± 1% of Full Scale
• Measurement Range: 20 - 40,000,000 mPas
• 126 Ranges of Measurement
• 21 Speeds with 6 Different Spindles

The 6R Viscotester is used with medium-viscous substances. It is the standard viscometer for 80% of all viscosity measurements. It is especially suited for the medium viscosity range extending from sewing machine oil up to PVC plastisols or whipped cream.

This Gilson Pipetman P2 Single Channel Pipette is used and in excellent condition.

Volume: 0.2 to 2 µL
This Mettler Toledo KB60s Scale Base is used and in excellent condition.

Configuration:
• Maximum Capacity: 60 kg, 120lb
This Thermo / Pierce Reacti-Therm III Heating Module is used and in excellent condition. This unit comes with 3 blocks inserted and the Reacti-Vap III 18785 top unit with 23 (out of a possible maximum of 27) insertion tubes installed.

Model: 18835

Included Reacti-Block Aluminum Blocks:
• (3) Q-1, Holds 10 mL Reacti-Vial Small Reaction Vials, 8 Holes (26 dia. x 46 mm deep)

Input Voltage: 120 VAC Only

Components Included:
• Weighted Base with Handles
• 24" Vertical Post with Safety Stop, Washer and Bolt

• Articulating Arm Assembly Terminating in 5/8" Bonder Socket Mount
• Accessory Pack:
  • (1) Lever Handle
  • (3) Allen Wrenches

View Photo of Accessory Pack.

This Waters 2410 Refractive Index Detector is used and in excellent condition.

Part Number: WAT053958

Configuration:
• Input Voltage: 100-240 VAC

• Dimensions: 11.2 x 19.8 x 8.2 inches
This Roper Scientific / Photometrics Quantix 1401E High-Resolution Digital Camera System is used and in excellent condition.

Included:

• International Power Sources PUP110-41-1-D1-S Power Source
     • Input: 100-240 VAC
     • Output: 110 W Max.

CCD Image Sensor:

• Type: C-Mount
• Model: 1401E

CCD Format:

• Sensor: KAF 1401E G2 (Grade 2), Scientific Grade
• Grade 2: ≤10 point defects, ≤4 cluster defects, ≤2 column defects
• Resolution (V x H): 1317 x 1035 Imaging Array, 6.8 x 6.8-µm Pixels
• Sensitivity: 50 µLux for 30-Second Exposure


Includes:
• Capacitance Extender: P/N 1652087 (125, 250, 500, 960 µF)
This Wescor 5500 Vapor Pressure Osmometer is incomplete and being sold for parts in as is condition. This unit is missing its Thermocouple head.
This Thermo / Lindberg / Blue M STF54454C 1700°C High Temperature Tube Furnaces is new from surplus stock. This unit is in excellent condition as shown in the photos. The controller is not included and sold separately. Several controllers are compatible with this furnace: CC59256PCOMC, CC59256PBCOMC, CC59256PCOM2KT, CC59256PBCOM2CKTC. Please contact manufacturer for pricing and availability of the Control Console and Remote Control Software.

This Item includes:
• STF54454C Tube Furnace
• 13 - 3” Diameter Ceramic Sleeve
• 4 - 2” Diameter Ceramic Sleeve
• 2 - 3” Diameter Ceramic Vestibules
• STF54434C Operating and Maintenance Manual (Applies to STF54454C)

Outside Dimensions (L x W x H) | 34" x 17" x 19"
Inside Chamber Dimensions | 3" Vestibule I.D. x 19" Long

View Photo of 3” Diameter Ceramic Sleeve
View Photo of 3” Diameter Ceramic Vestibules
View Photo of Ceramic Sleeves

This Anritsu HFT-40 Digital Surface Thermometer is used, and in excellent condition.

It comes with the N-347E-01 Wand and a Soft Leather Case.
This Fisher Scientific / Biotech TIV-88A Ultraviolet Transilluminator Model is used and in excellent condition.

Model # 88A

Type: Variable Intensity

Filter Area: 8 x 8 in. (20 x 20 cm)

This Waters Column Heater Module is used and in excellent condition.

Part Number: WAT03804


View Photo of the interior.

This General Transco / Electronetics EC-PBS-B Pulsating Bubble Surfactometer is used and in excellent condition.

Power Requirements:
• 90-132 VAC
• 47-63 Hz
• 1.5 A


This Corning PC-351 Hot Plate Stirrer is used and in good condition.
This Thermo / Lab-Line / Barnstead 685A Environ-Cab Humidity Chamber is used and in excellent condition. This unit does not include the D.I. Cartridge to filter the water. This unit also has slight rust on the bottom tray.

Configuration

• (3) Stainless Steel Shelves
• Chamber Volume: 10.4 ft3, 295L
• Chamber Dimension (W x H x D): 22" x 22" x 22"
• Total Dimensions (W x H x D): (Front) 32.5" x 25.25" x 48"
• Total Dimensions (W x H x D): (Back) 32.5" x 25.25" x 51"

View Photo of rust on the bottom tray.

This PTI D-104 Microscope Photometer is used and in excellent condition.

Configurations:

• 710 Photomultiplier Detection System Installed

If one component of this unit is desired, please contact Artisan Technology Group sales for pricing and availability.

The Thermo / Pierce Reacti-Therm III Heating/Stirring Module Triple-Block is used and in excellent condition. It comes with 3 blocks inserted and the Reacti-Vap III 18785 top unit with 27 (out of a possible maximum of 27) insertion tubes installed.

Model: 18935

Included Reacti-Block Aluminum Blocks:
• (1) A-1, Holds 0.3 or 1 mL Reacti-Vial Small Reaction Vials, 13 Holes (14 dia. x 23 mm deep)
• (1) C-1, Holds 3.5 mL Screw Cap Septum Vials, 13 Holes (15 dia. x 34 mm deep)
• (1) S-1, Holds 13 mm dia. Test Tubes, 13 Holes (14 dia. x 45 mm deep)

Input Voltage: 120 VAC Only

This Eppendorf CellTram Vario is Used, and in excellent condition. It ships as pictured. The valve and tubing will need to be refilled with CellTram Oil before being put into use.
This VWR 2002 Automatic CO2 Tank Switch is used and in excellent condition. The VWR 2002 is equivalent to the Shel Lab-labeled 2002-S.

Configuration:

• Input Voltage: 120 VAC

The Thermo / Pierce Reacti-Therm III Heating/Stirring Module Triple-Block is used and in excellent condition. It comes with 3 blocks inserted and the Reacti-Vap III 18785 top unit with 26 (out of a possible maximum of 27) insertion tubes installed.

Model: 18935

Included Reacti-Block Aluminum Blocks:
• (2) A-1, Holds 0.3 or 1 mL Reacti-Vial Small Reaction Vials, 13 Holes (14 dia. x 23 mm deep)
• (1) B-1, Holds 3 or 5 mL Reacti-Vials Small Reaction Vials, 9 Holes (21 dia. x 32 mm deep)

Input Voltage: 120 VAC Only

This Sartorius / Biohit eLine Lite Pipette Dispenser is new from surplus stock.

Includes:
• Instruction Manual

• Power Supply

Part Number: 730806

This Fastec Imaging TroubleShooter TS500ME Portable High-Speed Digital Video Camera is used and in excellent condition. This unit includes a Nikon Nikkor 50 mm f/1.2 lens and ac power adapter.

Part Number: TS500ME

Configuration:

• Frame Rate: 500 Frames per Second
• 1 GB Memory
• 8-Bit Monochrome Resolution
• C-Mount Lens Connector
• Compact Flash Port
• USB 2.0 Cable

Includes:

• Nikon Nikkor 50 mm F/1.2 lens
• AC Power Adapter
• Motion Measure Software Suite
• Quick Start Guides

View Photo of this unit's connectors

TroubleShooter TS500ME Balloon Drop MovieView Movie of high-speed Balloon Drop

This above video was taken by our technicians with the TroubleShooter TS500ME camera and then compressed the wmv for fast download.

This Digilab / Genomic Solutions HiGro High-Capacity Microwell Plate Growth System is used and in excellent condition.

Configuration:
• 96-Plate Format

• Air-Ready
• Burkert 6013A Electric Pump

Part Number: JHGA0926OH

View Photo of Burkert electric pump

This Davidson Optronics D-657-500 Tooling Autocollimator is used and in excellent condition. This unit comes in the original wooden case and includes a D416 Power Pack, D212 Adjustable Stand, Light Bulbs and plastic covers.

Model: D-657-500
Sensitivity: Nulls to 1 Arc Second
Accuracy: 5 Arc Seconds at 15 Arc Minutes
Nulling Repeatability: ±0.5 Arc Seconds or Better
Measuring Range: 30 Arc Minutes at 3 Feet
Aperature Diameter: 0.9"
Eyepiece Magnification: 12X
Focal Length: 12"
Light Source: GE #328 Lamp
115V Power Supply: Model D-416 Power Park, Variable From 6 Through 9 VDC

D416 Power Pack:
Input Voltage: 115 ±5 V
Output Voltage: 0 - 6 VDC
Output Current: 0.2 A

This IKA 3646000 ULTRA-TURRAX Tube Drive is used and in excellent condition. It ships in the original manufacturer's box with tubes, connectors, power adapter, and a hard copy of the manual.
This Parr Instrument 4636 Cell Disruption Vessel is used and in excellent condition.

Configuration
• Internal Volume: 1850 mL

• Maximum Sample Size: 1200 mL
• Maximum Working Pressure: 2200 psig
• Inside Diameter: 3.75"
• Inside Depth: 10.10"

Parts Included by Part Number:
• 583HCPG: Pressure Gauge, 3.5", 3000 psi
• A888HC
• Two A122VB: Needle Valve, 1/8" NPT, Male
• Two 260HC2: Valve Extension
• 591HC5: Dip Tube with Nut, 1850 mL
• 441HC: O-Ring, Neoprene
• 599HC22: Bomb Cylinder, 1850 mL, T316SS
• A816HC: Split Ring, Pair
• A811HC: Drop Band
• 811HC: Drop Band Bolt

This unit has some cosmetic damage that does not affect the operation.

Configuration:
• 12-Channel

• 20µL to 200 µL

View of this unit's damage

Corning Costar 12-Pette Manual (pdf)

This Illinois Instruments 4000 Oxygen Analyzer is new from surplus stock.

This Applied Energy Systems / Semi-Gas GSM-1A Gas Safety Monitor is used and in excellent condition.

GSM-1A Configuration:
• 75 psi Intake
This VWR 2 - 20 µL Single Channel Pipette is used and in excellent condition.
This Eppendorf Repeater Pro Pipette is used and in excellent condition. This unit includes the charging stand and AC adapter.
This Bio-Rad Bio-Dot Apparatus is used and in excellent condition. Unit does not include membrane, gasket support plate, or other consumables. Contact Bio-Rad for pricing and availability.

Configuration:
• Sample Template
• Sealing Gasket
• Vacuum Manifold
• Tubing and Flow Valve

This Vaisala GMT221 CO2 Transmitter is used and in excellent condition.

Part No: GMT221 M0N0B0A1A0B
Showing 1-100 of 476 Results
Contact Us
Fax:

(240) 376-1381