It is a low-cost termination accessory with 68 screw terminals for easy connection of field I/O signals to 68-pin DAQ products. The CB-68LPR has a right-angle mounted 68-pin connector. Dimensions: 7.62 by 16.19 cm (3.00 by 6.36 in.)
The Agilent E1502A 8-Channel Low-Pass Filter SCP provides eight fixed, 2-pole, low-pass filters with a 3 dB cutoff frequency of 7 Hz. It also provides input over-voltage protection and open transducer detection on each channel.
The Agilent E1503A 8-Channel Programmable Filter and Gain SCP provides eight programmable, 2-pole low-pass filters with cutoff frequency settings of 2, 10, and 100 Hz, as well as a 1.5 kHz "pass-through" mode (filter OFF). The eight programmable input amplifiers provide input voltage ranges of ± 0.25 V, ± 2 V, and ± 16 V. The E1503A SCP also provides input over-voltage protection and open transducer detection on each channel.
SC-2060 The SC-2060 has eight optically isolated digital inputs that are routed back to NI DAQ devices. These inputs have independent voltage reference connections and use optocoupler technology to sense digital signals with up to 400 Vrms of common-mode voltage. A digital signal 9 V below the reference is registered as a logical low. A digital signal 3 V below the reference reads as a logical high. The maximum current rating for each input is 20 mA. For applications with higher currents, use a resistor to limit the current.
This National Instruments SCXI-1520 8-Channel Universal Strain/Bridge Module is used and in excellent condition. Part Numbers: 186338B-01, 186338E-01, 186338D-01, 186338C-01, 186338F-01, 777966-20 Product Family: 6635-01-540-6191, 6635015406191
The Agilent E1508A 8-Channel x16 Gain & 7 Hz Fixed Filter SCP provides eight fixed, 2-pole, low-pass filters with a 3 dB cutoff frequency of 7 Hz and eight amplifiers with a gain of 16. It also provides input over-voltage protection and open transducer detection on each channel.
The Agilent E1501A Direct Input (>100 kHz BW) Signal Conditioning Plug-on, the most basic of Agilent Technologies' SCPs, provides eight hardwired paths that buffer the input signal. Each path has input over-voltage protection and open transducer detection.
The Agilent E1501A Direct Input (>100 kHz BW) Signal Conditioning Plug-on, the most basic of Agilent Technologies' SCPs, provides eight hardwired paths that buffer the input signal. Each path has input over-voltage protection and open transducer detection.
It is a low-cost termination accessory with 68 screw terminals for easy connection of field I/O signals to 68-pin DAQ products. The connector blocks include standoff feet for use on a desktop or mounted in a custom panel. The CB-68LP has a vertical-mounted 68-pin connector.
Dimensions: 14.35 by 10.74 cm (5.65 by 4.23 in.)
Part Number: 183030A-01, 183030B-01, 183030C-01, 183030D-01L
The Agilent E1513A 8-Channel Divide-by-16 Fixed Attenuator and 7 Hz Fixed Filter SCP provides eight fixed low-pass filters with a 3 dB cutoff frequency of 7 Hz and eight divide-by-16 attenuators. It also provides input over-voltage protection.
The Agilent E1510A 4-Channel Sample and Hold SCP provides four channels of sample and hold inputs, and four channels of direct inputs for the A/Ds. The sample and hold inputs sample all four channels simultaneously to reduce the skew introduced by scanning.
The SCP circuitry provides a voltage gain of 0.5, 8, 64, or 512 for each channel.
The low-pass filter on each sample and hold channel is a 6th order Bessel active RC filter used to provide alias protection and noise reduction. The filter cutoff frequencies are 1 kHz, 500 Hz, 250 Hz, 100 Hz, and 15 Hz.
This unit ships sealed in the manufacturer's bag. This unit includes a 0.2 m NB7 SC-205X Cable, Part Number: 180924-02.
SC-2060 The SC-2060 has eight optically isolated digital inputs that are routed back to NI DAQ devices. These inputs have independent voltage reference connections and use optocoupler technology to sense digital signals with up to 400 Vrms of common-mode voltage. A digital signal 9 V below the reference is registered as a logical low. A digital signal 3 V below the reference reads as a logical high. The maximum current rating for each input is 20 mA. For applications with higher currents, use a resistor to limit the current.
The Agilent E1422A and its companion products, the E1529A and E1539A, provide a breakthrough in lower cost for automated strain measurements. The E1422A requires E1539A SCPs to control Remote Signal Conditioning Units like the E1529A/B Remote Strain Conditioning Unit.
The Agilent E1512A 8-Channel 25 Hz Fixed Filter SCP provides eight fixed low-pass filters with a 3 dB cutoff frequency of 25 Hz. It also provides input over-voltage protection and open transducer detection on each channel.
This unit ships sealed in the manufacturer's bag. This unit does not include a terminal block.
Part Numbers: 184396A-01, 184396B-01, 777459-03 View National Instruments SC Signal Conditioning Connector Block. View National Instruments SCC Digital Input/Output Modules.
This unit ships in the sealed manufacturer's packaging.
Part Numbers: 188154C-01, 777459-37 View National Instruments SC Signal Conditioning Connector Block. View National Instruments SCC Digital Input/Output Modules.
SC-2060 The SC-2060 has eight optically isolated digital inputs that are routed back to NI DAQ devices. These inputs have independent voltage reference connections and use optocoupler technology to sense digital signals with up to 400 Vrms of common-mode voltage. A digital signal 9 V below the reference is registered as a logical low. A digital signal 3 V below the reference reads as a logical high. The maximum current rating for each input is 20 mA. For applications with higher currents, use a resistor to limit the current.
This Agilent / HP / Symmetricom 58502A Broadband Distribution Amplifier is used and in excellent condition.
Configuration: • Input Frequency Range: .1 MHz to 10 MHz • Input Amplitude Max: +15dBm • Input Amplitude Min: +7dBm • Output: Amplitude: +13dBm, +1dB/-3dB • Dimensions: 45 mm x 426 mm x 344 mm
This unit is also known as the Servotronix VRDM Servo Amplifier. Part Numbers: PRD-0051AMPF-Y0, PRD-O051AMPE-XO, PRD-0051AMPE-XO, 50045607, 50045707, PRD-0051AMPA-Y0, PRD-0051AMPA-X0, 50045603
This unit ships in the sealed manufacturer's static bag.
Part Numbers: 188154C-01, 777459-37 View National Instruments SC Signal Conditioning Connector Block. View National Instruments SCC Digital Input/Output Modules.
Part Numbers: 184396A-01, 184396B-01, 777459-03 View National Instruments SC Signal Conditioning Connector Block. View National Instruments SCC Digital Input/Output Modules.
This Agilent / HP 81578A Optical Attenuator is used and in excellent condition.
Configuration: • Insertion Loss: < 1.4 dB • Frequency: 700 - 1400 nm • Attenuation Range: 0 - 60 dB • Max Input Power: + 27 dB • Fiber Type: 62.5 / 125 μm MMF • Optical Interface: PC
Option 062 Typical IL's: • 1.0 dB (NA = 0.1) • 1.3 dB (NA = 0.2) • At Most 2.0 dB (NA = 0.2) • 3.0 dB (NA = 0.27)
This instrument includes the standard Agilent optical interface (View Photo). The Agilent 81000xI Series optical interface connectors are sold separately. They are available for purchase from our website here: (Item #50516).