This Sencore LC102 AUTO-Z Capacitor-Inductor Analyzer is used and in good condition. The battery needs to be replaced. The external power source is not included.

Included:

• Sencore SCR and Triac Accessory
• Sencore 39G201

This Fluke PM6304/023 Programmable Automatic RCL Meter is new from surplus stock. This unit ships in the original manufacturer's packaging with standard documentation.

Option 023: GPIB/IEEE-488 interface/Standard North American 120V Input Voltage

This Philips / Fluke PM6303A/03 Automatic RCL Meter is used and in excellent condition. This unit includes the PM9541B cable.

Part Number: PM6303A/03

Product Family: 6625-01-464-0906, 6625014640906

This Philips / Fluke PM6303A/03 Automatic RCL Meter is used and in excellent condition.

Part Number: PM6303A/03
Product Family: 6625-01-464-0906, 6625014640906
This IET / General Radio 602-K Decade Resistance Box is used and in excellent condition.
This Fluke PM6304/023 Programmable Automatic RCL Meter is used and in excellent condition.

Option 023: GPIB/IEEE-488 interface/Standard North American 120V Input Voltage
Option 02:
Substitutes fixed resistors for the standard variable potentiometers
. The values selected allow both Channels A and B to be programmed from 100 Ω to 409,500 Ω in 100 Ω steps.
This Fluke PM6304/023 Programmable Automatic RCL Meter is used and in excellent condition. Unit includes 2 sets of probes, and an SMD Test Fixture.

Configuration:

• PM 9540/TWE: SMD Tweezers
• PM 9541B: 4-wire Test Cable Set with Heavy Kelvin Clips
• PM 9542/SMD: Test Fixture for SMDs
• Option 023: GPIB/IEEE-488 interface/Standard North American 120V Input Voltage

View Photo of Probes and Test Fixture

This IET / GenRad 1482-L Standard Inductor is used and in excellent condition.

Inductance Valus: 100 mH
This LI-COR Biosciences LI-1000 Datalogger is used and in good condition. The AC Adapter, additional cables, and accessories are not included. The LI-1000 Datalogger will run on 6 D-Cell batteries, (batteries are not included).

Included:
• LI-1000 Datalogger
• LI-190SA Quantum Sensor
• Transport Case (Case latch is broken)

This Agilent / HP 4271B Digital LCR Meter is used and in excellent condition.

Options Installed:

• 001 - DC Bias Supply; 0.0 V to 39.9 V
• 101 - HP-IB Data Output and Remote Control

This GenRad 1656 Impedance Bridge is used and in excellent condition.

This Fluke PM6304/043 Programmable Automatic RCL Meter (w/o GPIB or RS232) is used and in good condition. The protective glass panel is missing, but this does not affect the functionality of the unit.

Configuration:
• PM 9565: DC Measurement Option Installed
• Option 043: DC measurement/Standard North American 120V Input Voltage (GPIB has been removed)

The LI-1000 Datalogger will run on 6 D-Cell batteries, (batteries are not included).

Included:
• LI-1000 Datalogger

• AC Power Adapter; Part Number: 1000-02
• (2) 37-Pin "D" Connector; Part Number: 1000-12
• Carrying Case, Part Number: 1000-07

View Photo of accessories.

Option 2T:
Substitutes fixed resistors for the standard variable potentiometers
. The values selected allow both Channels A and B to be programmed from 100 Ω to 409,500 Ω in 20 Ω steps.
Option 10:
Substitutes fixed resistors for the standard variable potentiometers
. The values selected allow both Channels A and B to be programmed from 10 Ω to 40,950 Ω in 10 Ω steps.
The LI-1000 Datalogger will run on 6 D-Cell batteries, (batteries are not included).

Included:
• LI-1000 Datalogger

• Transport Case (Case latch is broken)
This unit is missing the battery cover and has some blemishes to the case around the battery, this however does not effect its functionality.

Configuration:

• Test Frequency: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
• Frequency Accuracy: ± 0.1%
• Test Levels: 1 Vrms, 0.25 Vrms, 0.05 Vrms, 1 VDC (for DCR)
• Level Accuracy: ± 5&
• Output Impedance: 100 Ω, ± 5%

View Photo of Blemishes

Configuration:
• Option 101: HP-IB Digital Bus Connector
Option 01:
Substitutes fixed resistors for the standard variable potentiometers
. The values selected allow both Channels A and B to be programmed from 100 Ω to 409,500 Ω in 10 Ω steps.