30 / 30 Results
Items/Page
Advantest Q8381A Optical Spectrum Analyzer
Configuration
• Connector Type: FC
• Fiber Type: Freespace
• Wavelength Range: 350-1750 nm
• Measuring Range: -60 dBm to 10 dBm
(...)
• Max Input: 10 dBm
• Resolution: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

Keysight / Agilent 86142A Benchtop High-Accuracy Optical Spectrum Analyzer
This Agilent / HP 86142A Benchtop High-Accuracy Optical Spectrum Analyzer is used and in excellent condition.

Features:

(...)
• Optical Interface: PC*
• Wavelength Range: 600-1700 nm
• OS Version: A.01.01
• Firmware Version: B.03.01

*This instrument includes the standard Agilent optical interface (View Photo). The Agilent 81000xI Series optical interface connectors are sold separately. They are available for purchase from our website here: (Item #50516).

Keysight / Agilent 86142B Benchtop High-Accuracy Optical Spectrum Analyzer
This Agilent / HP 86142B Benchtop High-Accuracy Optical Spectrum Analyzer is used and in excellent condition. This unit includes handles.

(...)
Features:

• Optical Interface: PC*
• Wavelength Range: 600-1700 nm
• OS Version: A.02.00
• Firmware Version: B.06.02

*This instrument includes the standard Agilent optical interface (View Photo). The Agilent 81000xI Series optical interface connectors are sold separately. They are available for purchase from our website here: (Item #50516).

BYK Gardner Color-Guide Sphere Portable Spectrophotometer
This BYK Gardner Color-Guide Sphere Portable Spectrophotometer is used and in excellent condition. This unit includes a hard-sided case and accessories.

Catalog Number: 6830
(...)

View Photo of included accessories.

Advantest Q8381 Optical Spectrum Analyzer
Configuration:
• Connector Type: FC
• Fiber Type: Freespace
• Wavelength Range: 0.6 to 1.75 μm
(...)
• Measuring Range:
  • -80 dBm to +10 dBm (1.1 μm to 1.6 μm)
  • -70 dBm to +10 dBm (0.7 μm to 1.6 μm)
  • -60 dBm to +10 dBm (0.6 μm to 1.75 μm)
• Max input: +10 dBm
• Resolution: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

Keysight / Agilent 86142A Benchtop High-Accuracy Optical Spectrum Analyzer
This Agilent / HP 86142A Benchtop High-Accuracy Optical Spectrum Analyzer is used and in excellent condition.

Features:

(...)
• Optical Interface: PC*
• Wavelength Range: 600-1700 nm
• OS Version: A.02.00
• Firmware Version: B.06.02

*This instrument includes the standard Agilent optical interface (View Photo). The Agilent 81000xI Series optical interface connectors are sold separately. They are available for purchase from our website here: (Item #50516).

Yokogawa / Ando AQ8460 Optical Component Analyzer
This Yokogawa / Ando AQ8460 Optical Component Analyzer is used and in excellent condition. A User's Manual is included.

System(...)
Configuration:


AQ8460:
• Wavelength: 1500 to 1580 nm
• Optical Interface: FC/APC

Software Version:
• Host Ver. : 01.00.50
• Sub. : 01.10.70
• LD: 01.00.00

Serial Number: 03139501
Exfo IQ-5240 High-Performance Optical Spectrum Analyzer
Model Number IQ-5240
Connector: PC*
(...)

*This unit comes with the standard Exfo optical interface as shown here. The Exfo Universal Interface (EUI) Connector Adapters are sold separately. They can be purchased here.

Thorlabs / Exfo / Burleigh SA Plus High-Resolution Laser Spectrum Analyzer
This Burleigh / Exfo SA Plus High-Resolution Laser Spectrum Analyzer is used and in excellent condition.
dBm Optics 2004 Component Spectrum Analyzer System
FC/Freespace Optical Connector for Channel Inputs, Power Ref Input and Wavelength Ref Input

FC/APC Optical Connector for All Other Inputs and Outputs

3 Input Channels(...)


(2) FC/APC-FC/APC Short, Singlemode Fiber Optic Cables Provided for the Power Reference and Wavelength Reference Connections. View Photo of Cables.

Model 2004 Configuration:

• Option OMA-940: Optical Return Loss (ORL)
• Option OMM-301: Power Reference Module(includes OMU-931)
• Option OMM-401: Wavelength Reference Meter
• Option OMA-801: 8-Port Digital Output

Yokogawa / Ando AQ-1425 Optical Spectrum Analyzer
Configuration:

• Optical Interface: FC
• Fiber Type: Free Space
• Wavelength Range: 400-1600 nm
(...)
• Level Measuring Range: -60 to +10 dBm/resolution (at 600 to 1000nm)
• Level Measuring Range: -550 to +10 dBm/resolution (at 400 to 1600nm)
• Wavelength Accuracy: ±1 nm

Yokogawa / Ando AQ-6310B Optical Spectrum Analyzer
This Ando AQ-6310B Optical Spectrum Analyzer is used and in excellent condition. This unit operates from 120-240 VAC. However the Video Output BNC on the back panel for external video only operates(...) at 220-240Vac.

Measurement Level Range:

-80 to +10dBm / Resolution (600 to 1600 nm)
-70 to +10dBm / Resolution (400 to 1750 nm)

Configuration:

• Video Output: Approximately 1Vp-p; Composite Video Signal; 75 ohm Load; BNC Connector
• Analog Output: 0 to 5 V; 1kohm or more Load; BNC Connector
• Level Scale: 0.2 to 10dB / div and LINEAR
• Wavelength Sweep Width: 0.0 to 150 nm/div
• Dimensions: 11"H x 17"W x 18"D
• Weight: Approximately 66 lbs

Keysight / Agilent 86143B Portable Standard Performance Optical Spectrum Analyzer
This Agilent / HP 86143B Portable Standard Performance Optical Spectrum Analyzer is used and in excellent condition.

Features:
• Optical Interface: FC/PC
(...)
Opt 006: Wavelength Calibrator - The wavelength calibrator option provides an onboard wavelength reference that can be used to automatically calibrate the optical spectrum analyzer. The calibrator is based on an EELED and an Acetylene gas absorption cell. The wavelength calibrator enhances the OSA to achieve better than ±10 pm wavelength accuracy and removes the need to use a tunable laser source and multi-wavelength meter as an external reference.
• Face Cover Plate
• Agilent 8614x Series Amplifier Test Application User's Guide
• Agilent 8614x Series Passive Component Test Application User's Guide
• Agilent N1031A Benchlink Lightwave Manual & Drivers CD-ROM

This instrument includes the standard Agilent optical interface (View Photo). The Agilent 81000xI Series optical interface connectors are sold separately. They are available for purchase from our website here: (Item #50516).

Anritsu MS9001B1 Optical Spectrum Analyzer
This Anritsu MS9001B1 Optical Spectrum Analyzer is used, and in excellent condition.

Optical Interface: FC

Input Voltage: 120 VAC
Newport SR-160-CF Fiber Adapted Super Cavity Optical Spectrum Analyzer
This Newport SR-160-CF Fiber Adapted Super Cavity Optical Spectrum Analyzer is used and in excellent condition. This unit features a fitted wooden case with accessories. SR-UCC Universal Cavity(...) Controller is sold separately.

View Photo of closed case.
View Photo of accessories.

Configuration:

• Wavelength Range: 1300-1350 nm
• Center Wavelength: 1325
• Free Spectral Range: 6 GHz
• Optical Connector: FC/PC

Part Number: SR-160-CF
• SR-160-CF: High Transmission Fiber Adapted SuperCavity

Keysight / Agilent 86140B Benchtop Standard Accuracy Optical Spectrum Analyzer
This Agilent / HP 86140B Benchtop Standard Accuracy Optical Spectrum Analyzer is used and in excellent condition.

Configuration:
• Wavelength Range: 600 nm to 1700 nm
(...)
• Span Range: 0.2 nm to Full Range and Zero Span


Keysight / Agilent 86141B Benchtop Flexible Optical Spectrum Analyzer
This Agilent 86141B Benchtop Flexible Optical Spectrum Analyzer is used, and in excellent condition. It functions as a standard OSA when one of the two Monochrometer Output connectors are connected(...) to the Photodetector Input via a PC-PC fiberoptic jumper cable.

Features:
• Optical Interface: PC
• Optical Input: 9/125 µm
• Photodetector Input: 50/125 µm
• (2) Monochromator Outputs: 9/125 µm and 50/125 µm
Opt 004: 1300/1550 Internal EELED Source
Opt 006: Wavelength Calibrator - The wavelength calibrator option provides an onboard wavelength reference that can be used to automatically calibrate the optical spectrum analyzer. The calibrator is based on an EELED and an Acetylene gas absorption cell. The wavelength calibrator enhances the OSA to achieve better than ±10 pm wavelength accuracy and removes the need to use a tunable laser source and multi-wavelength meter as an external reference.
Opt H17: Modification to provide preselector capability for single mode (9/125 um) applications. The internal transfer switch has been removed. This special option requires a jumper to be installed on the front panel from monochromator output to photodetector input for OSA operation.
• Internal applications: Passive Components, WDM Spectrum, Amplifier Test, Source Tests, Filter Mode, and Power Meter Mode

Our technician measured the folowing:
Click here for output spectrum of the 1300 nm EELED source viewed with an Anritsu OSA.
Click here for output spectrum of the 1550 nm EELED source viewed with an Anritsu OSA.
Click here for output spectrum of the Calibrator viewed with an Anritsu OSA.


This instrument includes the standard Agilent optical interface (View Photo). The Agilent 81000xI Series optical interface connectors are sold separately. They are available for purchase from our website here: (Item #50516).

Yokogawa / Ando AQ8460 Optical Component Analyzer
This Yokogawa / Ando AQ8460 Optical Component Analyzer is used and in excellent condition. A User's Manual is included.

System(...)
Configuration:


AQ8460:
• Wavelength: 1500 to 1580 nm
• Optical Interface: FC

Software Version:
• Host Ver. : 01.01.17
• Sub. : 01.14.11
• Ld: 01.00.00

Serial Number: 03139501
Keysight / Agilent 86082A Wavelength Domain Component Analyzer
This Agilent / HP 86082A Wavelength Domain Component Analyzer is used and in excellent condition. This unit requires the Agilent / HP 8164A Lightwave Measurement System with Tunable Laser. (...)

Configuration:

• Optical Interface: PC*
• Fiber Type: Singlemode, 9/125 µm
• Software Rev.: C.01.02.A.02.00
• Factory Calibration Date: 17 April 2001

This instrument includes the standard Agilent optical interface as seen here. The Agilent 81000xI Series optical interface connectors are sold separately. They are available for purchase from our website here: (Item #50516).

The Agilent / HP 8164A Lightwave Measurement System can be purchased from our website here: (Item #50659). The Agilent / HP 81680A Module can be purchased from our website here: (Item #69941).


Keysight / Agilent 86140A Benchtop Standard Accuracy Optical Spectrum Analyzer
This Agilent / HP 86140A Benchtop Standard Accuracy Optical Spectrum Analyzer is used and in excellent condition.

Configuration:
• Wavelength Range: 600 nm to 1700 nm
(...)
• Span Range: 0.2 nm to Full Range and Zero Span


Yokogawa / Ando AQ8460 Optical Component Analyzer with AQ8461 Expansion Frame
This Yokogawa / Ando AQ8460 Optical Component Analyzer with AQ8461 Expansion Frame is used and in excellent condition. This unit includes the AQ8461 expansion mainframe with (1) AQ8461-23 8-Channel(...) Sensor Module installed. A User's Manual is included.

System Configuration:


AQ8460:
• Wavelength: 1500 to 1580 nm
• Optical Interface: FP/APC

Software Versions:
• Host Ver.: 01.00.50
• Sub Ver.: 01.10.70
• LD Ver.: 01.00.00

AQ8461-23:
• Optical Interface: PC*

*The Anritsu J14 / J06 Series Quick Release Optical Connectors are sold separately. They are available for purchase from our website here: (Item #62894).


Keysight / Agilent 85027D Directional Bridge
Configuration:
• Frequency Range: .01 - 47 GHz
• Nominal Impedance: 50 ohms
• Connector Input: 2.4 mm (f)
(...)
• Connector Test Port: 2.4 mm (f)


Advantest Q83811 Optical Preselector
The Q83811 Optical Preselector can be configured with the Q8381 / Q8382 Optical Spectrum Analyzer to achieve a higher dynamic range. This unit does not include the power or control cables.
Advantest Q83811 Optical Preselector
The Q83811 Optical Preselector can be configured with the Q8381 / Q8382 Optical Spectrum Analyzer to achieve a higher dynamic range. This unit does include the power and control cables; Part(...) Numbers: SS3330X01 03 and SS2245X02 02, respectively.

Configuration:
• Power Cable Approximate Length: 20.5 in.
• Control Cable Approximate Length: 18.5 in.

View Photo of power and control cables.

Yokogawa / Ando AQ-1425 / AQ1425 Optical Spectrum Analyzer
This unit is in fair condition. It has some exterior dents and dings.

Configuration:

• Optical Interface: Biconic
(...)
• Fiber Type: Free Space
• Wavelength Range: 400-1600 nm
• Level Measuring Range: -60 to +10 dBm/resolution (at 600 to 1000nm)
• Level Measuring Range: -550 to +10 dBm/resolution (at 400 to 1600nm)
• Wavelength Accuracy: ±1 nm

View Representative Photo of exterior dents and dings.

Keysight / Agilent 86141B Power Switch Repair
This is a repair item for a Agilent / HP 86141B Power Switch Repair.