15 / 48 Results
Sort By
Items/Page
Excelitas / Lumen Dynamics 0.12 Inch / 45.75 in. Light Guide Probe
Configuration:
• Spot Diameter, Exterior: Approximately 0.12 in. (3 mm)
(...)
• Connector Diameter, Exterior: Approximately 0.37mm (9.29 mm)
• Cable Length: Approximately 45.75 in. (1162 mm)
• Probe Length: Approximately 2.5 in (63.5 mm)

Exfo 012-65000 200-Watt Mercury Arc for Surface Cure with Intelli-Lamp Technology
Configuration:
• Lamp Hours: 40
(...)
• Maximum Intensity Output: 16880 mW/cm2 (350-500nm Bandpass)

Part Number: 012-65000

Excelitas / Lumen Dynamics P1000 Ultracure 100SS Plus UV Curing Module
This unit is also known as the EXFO P1000 Ultracure 100SS Plus UV Curing Module. This unit has a high pressure mercury lamp, which is used and has unknown remaining life. The remote cable is not(...) included.

Light Guides are Sold Separately here

Excelitas / Lumen Dynamics Novacure N2001-A1 Spot Curing System
This unit is also known as the EFOS Novacure N2001-A1 Spot Curing System.

Options Installed
320-500 nm Filter
Lamp Life Upgrade(...)

PC and Novacure Software are not included
NR5000 Radiometer Upgrade
EMC Upgrade
StepCure
Fiber Light Guides are Sold Separately here

Dymax 2000-EC UV Curing Light Source Flood Lamp System
This Dymax 2000-EC UV Curing Light Source Flood Lamp System is used and in excellent condition. This unit includes the 2000-EC Flood, the EC-400 Power Supply, and an interface cable.The ZIP Shutter(...) and the Light Shield are sold separately.

Reported Lamps Hours: Between 20-50 hours Depending on Unit

Excelitas / Lumen Dynamics Light Guide Adapter
Configuration:
• Front End, Exterior Diameter: 0.39 in (9.8 mm)
• Back End, Exterior Diameter: 0.99 in (25.2 mm)
Excelitas / Lumen Dynamics Novacure N2000 Spot Curing System
This unit is also known as the EFOS Novacure N2000 Spot Curing System.

Configuration:
320-500 nm Filter
PC and Novacure Software are not included(...)

Lamp not included

Light Guides are Sold Separately here

Dymax 2000-EC UV Curing Light Source Flood Lamp System
This Dymax 2000-EC UV Curing Light Source Flood Lamp System is used and in excellent condition. This unit includes the 2000-EC Flood and the EC-400 Power Supply. The ZIP Shutter, the Light Shield,(...) and the interface cable are sold separately.

Reported Lamps Hours: Between 200-400 Hours Depending on Unit

Excelitas / Lumen Dynamics 0.12 in. / 49.5 in. Light Guide Probe
This unit has the white probe handle and wider cable.

Configuration:
(...)
• Spot Diameter, Exterior: Approximately 0.12 in. (2.88 mm)
• Connector Diameter, Interior: Approximately 0.39 in. (9.88 mm)
• Cable Diameter, Exterior: Approximately: 0.29 in. (7.31 mm)
• Cable Length: Approximately 49.5 in. (1257.3 mm)
• Probe Length: Approximately 2.5 in. (63.5 mm)

Texas Instruments TMS27C240-10 UV Erasable Chip
Configuration:
• Max Access / Min Cycle Time (VCC ± 10%): 100ns
Excelitas / Lumen Dynamics 0.27 in. / 114 in. Light Guide Probe
This unit has a cracked cable cover; however, this does not affect its ability to function properly.

Configuration:
(...)
• Spot Diameter, Exterior: Approximately 0.27 in. (6.86 mm)
• Connector Diameter, Interior: Approximately 0.46 in. (11.68 mm)
• Cable Diameter, Exterior: Approximately: 0.35 in. (8.89 mm)
• Cable Length: Approximately 114 in. (2895.6 mm)
• Probe Length: Approximately 0.81 in. (20.574 mm)

View Photo of cracked cable cover.

Dymax EC-400 Power Supply
This Dymax EC-400 Power Supply is used and in excellent condition.

Reported Lamps Hours: Between 7700-7900 hours Depending on Unit
Exfo Novacure 2100 Spot Curing System
This unit is incomplete and does not include the built-in radiometer for calibrating the light intensity output. Please contact Exfo for pricing and availability of the radiometer. PC and Novacure(...) Software are not included.

320-500 nm Bandpass Filter Included
Fiber Light Guides are Sold Separately here

Exfo 012-60850 100-Watt Mercury Arc with Intelli-Lamp Technology
This is also known as the EXFO 012-60850 100-Watt Mercury Arc with Intelli-Lamp Technology.

Configuration:
(...)
• Lamp Hours: 333
• Maximum Intensity Output: 18755 mW/cm2 (350-500nm Bandpass)

Part Number: 012-60850