IKA C 2000 Basic Version 2 Calorimeter

IKA C 2000 Basic Version 2 Calorimeter



This IKA C 2000 Basic Version 2 Calorimeter is Brand new and includes full manufacturer's warranty.

IKA C 2000 Basic Version 2 Datasheet (pdf)
IKA C 2000 Basic Version 2 Manual (pdf)




Have a quote from somewhere else? Click Here
Stock # 62345-2
Quick Quote
Sell Yours
Repair Quote
  • More Info
  • Tech Specs
  • Additional Photos
  • Datasheets / Manuals 
  • View It Live Request 
Contact Us
Share:
IKA C 2000 Calorimeter

Features
  • Automatic Water Handling System
  • Automatic oxygen Filling of Decomposition Vessel
  • Automatic Decomposition Vessel Identification
  • Automatic Sample Ignition
  • Isoperibol Measurement Time of Approximately 22 min
  • Dynamic Measurement Time of Approximately 7 min
  • Compact, Integrated Modular Design for Convenient Operation
  • Eight Interface Connections

Description

The C 2000 basic IKA- calorimeter is a combustion calorimeter for determining gross calorific values of liquid and solid samples. A high level of automation with extremely simple handling characterizes this instrument. In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available. To provide the calorimeter with cooling water, it needs to be connected to a thermostat f.e. IKA KV 600 ( accessory) or a firmly installed water connection. The C 2000 basic is equipped with a very convenient console to operate the unit.


Product Family: C 2000, C2000, C-2000, C 2000 Basic Version 1, C 2000 Basic Version 2, C 2000 Basic High Pressure, C 2000 Control High Pressure, C 2000 Control Version 1, C Control Version 2,


Important Notice: Please note that any additional items included with this equipment such as accessories, manuals, cables, calibration data, software, etc. are specifically listed in the above stock item description and/or displayed in the photos of the equipment. Please contact one of our Customer Support Specialists if you have any questions about what is included with this equipment or if you require any additional information.


Contact Us
Share:

Specifications

Measuring range max.40000 J
Measuring mode adiabatic 22°Cno
Measuring mode isoperibol 22°Cno
Measuring mode dynamic 25°Cyes
Measuring mode isoperibol 25°Cyes
Measuring mode dynamic 3°Cyes
Measuring mode isoperibol 3°Cyes
Measuring mode double dry (ISO 1928)no
Measuring time dynamic approx.7 min
Measuring time isoperibol approx.22 min
Reproducibility dynamic (1g benzoic acid NBS39i)0.1 %RSD
Reproducibility isoperibol (1g benzoic acid NBS39i)0.05%RSD
Working temperature max. 30°C
Temperature measurement resolution 0.0001 K
Cooling medium temperature min.12°C
Cooling medium temperature max.28°C
Cooling medium permissible operating pressure1.5 bar
Cooling mediumtap water
Type of coolingflow
Flow rate min. 60 l/h
Flow rate max.70 l/h
Oxygen operating pressure max. 40 bar
Interface scaleRS232
Interface printerCentronix
Interface PCRS232
Interface test rackyes
Interface ext. monitoryes
Interface ext. keyboardyes
Oxygen fillingyes
Degasificationno
Decomposition detectionBasic Version 1, Basic Version 2, Basic High Pressure, Control Version 1, Control Version 2:yes
Control High Pressure: no
Decomposition vessel C 5010Basic Version 1: yes
Basic Version 2, Basic High Pressure, Control High Pressure, Control Version 2: no
Decomposition vessel C 5012Basic Version 1, Basic High Pressure, Control High Pressure, Control Version 1: no
Basic Version 2, Control Version 2: yes
Decomposition vessel C 7010no
Decomposition vessel C 7012no
Decomposition vessel C 62Basic Version 1, Basic Version 2, Control Version 1, Control Version 2: no
Basic High Pressure, Control High Pressure: yes
Analysis according to DIN 51900 (1977/84)yes
Analysis according to ASTM D240 (2002)yes
Analysis according to ASTM D4809 (2000)yes
Analysis according to ASTM D1989 (1992)yes
Analysis according to ASTM D5468 (2002)yes
Analysis according to ASTM D5865 (2001)yes
Analysis according to ASTM E711yes
Permissible ambient temperature20 - 25°C
Permissible relative moisture80%
Protection class according to DIN EN 60529IP 21
RS 232 interfaceyes
Voltage220 - 240 / 100 - 120 V
Frequency50/60 Hz
Power input1800 W


Contact Us
Share:

Item Images

Click a thumbnail to view larger image:

IKA C 2000 CalorimeterIKA C 2000 Calorimeter


Contact Us
Share:

View It Live

View equipment LIVE - Before you buy!

InstraView™ Equipment Inspection



Buying used equipment doesn't always have to be a shot in the dark. We know there are plenty of differences when it comes to used equipment and quite often, choosing between different pieces is difficult, especially when the equipment is not sitting right in front of you.

Well, what if you were able to see a piece of equipment before you purchased it? Not just a picture from the manufacturer's website, but the actual piece of equipment you would receive.
With InstraView™, we move you one step closer to inspecting the equipment you're interested in without having to wait for the equipment to show up at your door.

InstraView™ works in your web browser and allows you to view the actual piece of equipment you're interested in before purchasing. You can zoom in close to see the labels with the serial number or zoom out to see the overall condition of the equipment.

It's like having the store come to you!


InstraView Request Form

To get started:

  1.   Fill in the request form below
  2.   We'll send you an email letting you know exactly when your piece of equipment will be available for viewing

Name:
Email:
Item to Inspect: 62345-2 - IKA C 2000 Basic Version 2 Calorimeter


All you need is a web browser (ie. Microsoft Internet Explorer or Netscape) and Sun's Java Runtime Environment installed. If you need to install the Sun Java Runtime, you may download the latest Java SE Runtime Environment (JRE) http://www.oracle.com/technetwork/java/javase/downloads/index.html