## Summary

- Manufacturer: Tuttnauer
- Model: 5596 SP-1
- Condition: Parts Grade / As-Is
- Price: Quote only
- Availability: Not in Stock
- Warranty: No Warranty
- ITAR restricted: No
- Shipping weight: 800 lb
- Shipping dimensions: FREIGHT: 60X40X80 in

## Categories

- Lab & Analytical > Autoclaves (primary)

## Details

This Tuttnauer 5596 SP-1 55 Compact Series Autoclave is used and being sold without warranty. This unit was removed from a production facility. Our workplace does not have facility steam to fully test this unit, and have to sell the item untested / as-pictured.

This unit includes a spare autoclave door gasket, two spare printer paper rolls, and a pull-out tray.

### Facility Requirements

- Maximum Ambient Temperature: 40 C
- Maximum Humidity: 80%
- Do not use the Autoclave in the presence of dangerous gases and vapors

### Steam Requirements

- Building Supply Pressure: 4-6 bar (50-80 psi)
- Maximum distance of Steam Trap from Autoclave: 2 meters
- Steam Inlet Pipe Diameter: 1/2 inch

### Air Requirements

- Building Supply Pressure: 6-7.5 bar (90-110 psi)
- Air Inlet Pipe Diameter: 3/8 inch
- If there is no external air source, use a small compressor

### Water Requirements

- Tap Water Supply: Hardness should not exceed 0.7-2 mmol/l
- Tap Water Pressure: 4-6 bar (50-80 psi)
- Feed Water Pipe Diameter: 1/2 inch

### Drain Requirements

Connect the following outlets directly to a drain funnel or connect them through a drain collector pipe of 2 inches diameter that should be covered. The drain system should be vented. Connect the system drain by 3/4 inch diameter pipe.

### Configuration

- Chamber Dimensions (WxHxD) (mm):  20 in x 20 in x 38 in (510 mm x 510 mm x 970 mm)
- Chamber Volume (Liter):  250
- External Dimensions (WxHxD):  44 in x 75 in x 56 in (1120 mm x 1910 mm x 1430 mm)
- Input Voltage:  115 VAC

## Images

- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_closed_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_closed_view2.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_closed_view3.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_closed_view4.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_open_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_open_view2.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_open_view3.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_open_view4.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_front_panel_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_main_label_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_autoclave_label_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_open_autoclave_w_rack_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_open_autoclave_no_rack_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_cart_view1.jpg>
- <https://www.artisantg.com/itemimages/tuttnauer_5596sp_1_cart_view2.jpg>