Emerson / Rosemount Analytical Model Solu Comp II Dual Input pH / Conductivity Analyzers
  • Rosemount_SoluComp_1055_Series_View1
  • Rosemount_SoluComp_1055_Series_View2
  • Rosemount_SoluComp_1055_Series_View3
  • Rosemount_SoluComp_1055_Series_View4
  • Emerson_Rosemount_Analytical_1055_01_10_S1_DM_View1_2014115131024
  • Emerson_Rosemount_Analytical_1055_01_10_S1_DM_View2_2014115131024
  • Emerson_Rosemount_Analytical_1055_01_10_S1_DM_View3_2014115131024
  • Emerson_Rosemount_Analytical_1055_01_10_S1_DM_View4_2014115131024

Emerson / Rosemount Analytical Model Solu Comp II Dual Input pH / Conductivity Analyzers

Features

  • Single Or Dual Measurement With Dual 4-20 mA Outputs
  • Full Complement Of Measurement Combinations Can Be Commissioned In The Field
  • Three Fully Programmable Alarms
  • Broad Selection Of Measurement Choices

View our selection of these items below.






Contact Us
Share:



1055-01-10-S1-DM Configuration:
• Power: 115/230 VAC, 50/60 Hz
• Mounting: Panel Mounted Enclosure
• Field-Commissioned Suites: Suite 1 - Field Commissioned Measurement (Basic)
• Optional: Dual Measurement

Part Number: 9241393-00/F





1055-01-10-20 Configuration:
• Single Measurement
• Power: 115/230 VAC, 50/60 Hz
• Mounting: Panel Mounting Enclosure
• Measurement: Contacting Conductivity (0 to 20,000 uS/cm)






1055-01-11-20-32 Configuration:
• Dual Measurement
• Power: 115/230 VAC, 50/60 Hz
• Mounting: Pipe/Surface Mounting Enclosure
• Measurement 1: Contacting Conductivity (0 to 20,000 uS/cm)
• Measurement 2: pH/ORP (Option)

Part Number: 9241393-00/F




  • Description
  • Tech Specs
  • Datasheets / Manuals 
Contact Us
Share:

Description

The Emerson / Rosemount Solu Comp II analyzers offer the choice of single or dual sensor input with measurement choices of pH/ORP, esistivity / conductivity / TDS, % concentration, ratio conductivity, total and free chlorine, dissolved oxygen, dissolved ozone, flow and temperature. Dual measurement analyzers offer a wide choice of measurement combinations thus reducing the cost per loop and needed panel space.

The Solu Comp II can be ordered with the ability to commission measurements in the field. This added flexibility can greatly reduce the number of spare instruments required for field servicing. Exclusive Quick Start screens appear the first time the Solu Comp II is powered up. Screen prompts direct the user to register the number of sensors, the measurement unit(s) and the language to display. Some measurement specific prompts are also displayed. The measurement loop is ready for use in a matter of minutes.

Menu screens for calibrating and registering choices are simple and intuitive. Plain language prompts guide the user through the procedures. There are no service codes to enter before gaining access to menus. The Solu Comp II accepts single or dual sensor input. The two 4-20 mA outputs can be independently programmed to correspond to any selected measurement or temperature. Output damping and linear or log output may also be field selected. The Solu Comp II has three fully programmable alarm relays that can be assigned to any selected measurement or temperature. Alarms can be configured as high, low, or USP1. The third relay has the additional choice of fault alarm operation. When selected, a fault alarm will activate the relay when a sensor or analyzer fault occurs.

Product Family: SoluCompII-1055, Solu-Comp-II, SoluComp-II, Solu Comp II, SoluCompII
Contact Us
Share:

Specifications