Wavelength Calibration at 20°C:
• 325 nm: -2.329
• 365 nm: -1.781
• 405 nm: -1.405
• 436 nm: -1.198
• 546 nm: -0.737
• 589.3 nm (EP): -0.627
• 589.44 (UPS): -0.627
• 633 nm: -0.539
• 587/ISS: -1.810°Z
• 589/ISS: -1.810°Z
• 880/ISS: -1.813°Z
• 882/ISS: -1.813°Z





Have a quote from somewhere else? Click Here
Stock # 90167-1
Quick Quote
Sell Yours
Repair Quote
  • More Info
  • Tech Specs
  • Additional Photos
  • Datasheets / Manuals 
  • View It Live Request 
Contact Us
Share:
Rudolph Research TempTrol / Standard Series Quartz Control Plate Calibration Standards

Features
  • Single and 3 Rotation Versions of Quartz Plates
  • Calibrated in °Arc and °ISS/°Z
  • (1) Left or Levo Turning Quartz Plate
  • (1) Right or Dextro Turning Plate
  • Reported Uncertainty of ±0.002° Arc at 589

Description

The Rudolph Research TempTrol / Standard Series Quartz Control Plate Calibration Standards provide a permanent calibration standard for polarimeters and saccharimeters. Every Rudolph calibration standard is manufactured using extremely stable crystalline quartz which is manufactured and polished to specific planeness, parallelism, purity and axis standards. These standards meet or exceed the National Institute for Standards and Technology (NIST) Circular C440 or as laid down by the International Commission for Uniform Methods of Sugar Analysis (ICUMSA). Each Quartz Plate comes complete with a label showing calibration at 11 different wavelengths.

Quartz Plates come in single and 3 Rotation Quartz Plates. Single Quartz Plates have a single rotation value at each wavelength and are calibrated in °Arc (Optical Rotation) and °ISS/°Z (Sugar Degrees). 3 Rotation Quartz Plates are also calibrated in °Arc and °ISS/°Z, but have three rotation values at each wavelength. This is possible because each plate is made up of one left or levo turning Quartz Plate (i.e. -28° Arc) and one right or dextro turning plate (i.e. +30° Arc) which may be used separately or together for a combined rotation of 2°Arc (30°-28°). Every Rudolph Research Analytical Quartz Plate is manufactured to a reported uncertainty of ±0.002° Arc at 589.


Product Family: TempTrol Quartz Plate Calibration Standard, Standard Quartz Plate Calibration Standard, A700T-1, A700-1, 302T, 302, 300T-S, 300-S, A700T-2, A700-2, 301T-S, 301-S, 302T-S, 302-S


Important Notice: Please note that any additional items included with this equipment such as accessories, manuals, cables, calibration data, software, etc. are specifically listed in the above stock item description and/or displayed in the photos of the equipment. Please contact one of our Customer Support Specialists if you have any questions about what is included with this equipment or if you require any additional information.


Contact Us
Share:

Specifications

Contact Us
Share:

Item Images

Click a thumbnail to view larger image:

Rudolph Research TempTrol / Standard Series Quartz Control Plate Calibration StandardsRudolph Research TempTrol / Standard Series Quartz Control Plate Calibration StandardsRudolph Research TempTrol / Standard Series Quartz Control Plate Calibration Standards


Contact Us
Share:

View It Live

View equipment LIVE - Before you buy!

InstraView™ Equipment Inspection



Buying used equipment doesn't always have to be a shot in the dark. We know there are plenty of differences when it comes to used equipment and quite often, choosing between different pieces is difficult, especially when the equipment is not sitting right in front of you.

Well, what if you were able to see a piece of equipment before you purchased it? Not just a picture from the manufacturer's website, but the actual piece of equipment you would receive.
With InstraView™, we move you one step closer to inspecting the equipment you're interested in without having to wait for the equipment to show up at your door.

InstraView™ works in your web browser and allows you to view the actual piece of equipment you're interested in before purchasing. You can zoom in close to see the labels with the serial number or zoom out to see the overall condition of the equipment.

It's like having the store come to you!


InstraView Request Form

To get started:

  1.   Fill in the request form below
  2.   We'll send you an email letting you know exactly when your piece of equipment will be available for viewing

Name:
Email:
Item to Inspect: 90167-1 - Rudolph Research Standard Quartz Control Plate with 3 Rotations


All you need is a web browser (ie. Microsoft Internet Explorer or Netscape) and Sun's Java Runtime Environment installed. If you need to install the Sun Java Runtime, you may download the latest Java SE Runtime Environment (JRE) http://www.oracle.com/technetwork/java/javase/downloads/index.html