Rod-L M100DC Series DC Hipot Test Instruments
  • rod_l_m100dc_view1
  • rod_l_m100dc_view2
  • rod_l_m100dc_view3
  • rod_l_m100dc_view4

Rod-L M100DC Series DC Hipot Test Instruments

Features

  • Up to 5.5KV DC Dielectric Test
  • Concurrent Ground Continuity Test
  • ARC and OVERCURRENT Detection Circuits
  • Fast HV Shutdown

View our selection of these items below.


Have a quote from somewhere else? Click Here




Contact Us
Share:



This Rod-L Model M100DC DC Hipot Test Instrument is used, in excellent operational, and good physical condition.

Labeled Model Number:
M100DC-5.5-5
Max Current Output: 5 mA



Stock # 47539-6




This Rod-L Model M100DC DC Hipot Test Instrument is used, in excellent operational, and good physical condition. This unit has an auto-switching power supply. This unit does not include the burn/test switch or the side handles.

Labeled Model Number:
M100DC-5.5-5
Max Current Output: 5 mA



Stock # 47539-7




This Rod-L Model M100DC DC Hipot Test Instrument is used, in fair operational, good physical condition and is being sold as-is. This unit if functional, however it requires a manufacturers adjustment/calibration. The unit has been priced accordingly.

Labeled Model Number:
M100DC-5.5-5
Max Current Output: 5 mA



Stock # 47539-10




This Rod-L 00381-02 is the M100DC DC Hipot Test Instrument DC Control Logic Board.

Part Number: 00381-03



Stock # 47539-8




This Rod-L 00383-02 is the M100DC DC Hipot Test Instrument Motherboard.

Part Number: 00384-03



Stock # 47539-9




This Rod-L 1516 is the M100DC DC Hipot Test Instrument Transformer.

Part Number: 84-23



Stock # 47539-11




This Rod-L M100D is the M100DC DC Hipot Test Instrument High Voltage Power Supply.



Stock # 47539-12




This is the Rod-L M100DC DC Hipot Test Instrument Mounting Kit.



Stock # 47539-13




This Rod-L Model M100DC DC Hipot Test Instrument is used, in excellent operational, and good physical condition.

Labeled Model Number:
M100DC-5.5-100
Max Current Output: 10 mA



Stock # 47539-1




This Rod-L Model M100DC DC Hipot Test Instrument is used, in excellent operational, and good physical condition.

Labeled Model Number:
M100DC-5.5-1.0
Max Current Output: 10 mA
AC Hipot Tester Interface Option Installed



Stock # 47539-2




This Rod-L Model M100DC DC Hipot Test Instrument is used, in excellent operational, and good physical condition.

Labeled Model Number:
M100DC-5.5-100
Max Current Output: 10 mA
Remote Control Option Installed



Stock # 47539-3




This Rod-L Model M100DC DC Hipot Test Instrument is used, in excellent operational, and good physical condition.

Labeled Model Number:
M100DC-5.5-100
Max Current Output: 1 mA



Stock # 47539-4




This Rod-L Model M100DC DC Hipot Test Instrument is used in good condition.

Labeled Model Number:
M100DC-5.5-500
Max Current Output: 500 µA
Max DC Voltage Out: 6kV
Remote Control Option Installed
Rackmount Handles Installed



Stock # 47539-5




This Rod-L HV Connector Cable is used and in excellent condition. This cable is used to connect multiple Rod-L Hipot and Ground Testers together.



Stock # 47552-11



  • Description
  • Tech Specs
  • Datasheets / Manuals 
Contact Us
Share:

Description

• Performs dc dielectric withstand test up to 5.5 KVDC at 10 milliamperes (5mA standard)
• Performs concurrent ground continuity test
• ARC and OVERCURRENT detection circuits
• Fast HV shutdown within 2 milliseconds
• Fast discharge of Device Under Test (DUT) and other test standards
• Production/Quality Assurance Testing
• Fully automatic test cycle

Detects and indicates the following:

• Test Ready (security ground chassis sensed)
• Test in Progress
• Test Passed
• Test Failed

Following test parameters easily preset via rear panel potentiometers:

• Voltage ramp
• Test time
• Test voltage
• Overcurrent trip point
• Switch-selectable ramp and rest time combinations
• Arc detection circuit

• Overcurrent detection circuit
• Solid state HV generation and control system for reliability
• Switchable "burn" featured permits destructive testing by maintaining output voltage, following failure, to the DUT throughout duration of preset test time
• Can be interconnected with M25 Ground Continuity Test Instrument or any ROD-L AC Hipot Test Instrument to simplify multiple testing requirements

Continuos Ground Continuity Monitoring:

• Monitors Ground Continuity of DUT before and during each Hipot Test
• Senses for 0.5 ohm (standard), at approximately 1.5 VAC
• Loss of safety ground connection during test causes high voltage to shut down with both audible and visual failure indication
• Inhibits application of high voltage if the security chassis ground is not secure

Superior Safety Features:

• Front panel receptacle is rated to 8000 VAC
• Front panel receptacle prevents direct operator exposure to high voltage during test
• Shutdown within 2 milliseconds after dielectric breakdown, overcurrent or ground continuity fault
• Electronically controlled output voltage ramp rate circuit guarantees consistently smooth ramp
• Visual (audible optional) indication of high voltage applied to DUT
• Discharge circuit provides for rapid discharge of DUT following shutdown

Visual and audible indication of the following:

• Arc detection
• Excessive overcurrent flow
• Ground continuity test failure

Product Family: M100DC, M100DC-5.5-500, M100DC5.5500, M100DC 5.5 500, M100DC-5.5-100, M100DC5.5100, M100DC 5.5 100
Contact Us
Share:

Specifications

Contact Us
Share:

Resources

Manuals, Datasheets, Drivers, Links

Rod-L M100DC Datasheet (pdf) 
Rod-L M100DC Manual (pdf) 
Rod-L M100DC Quick Start Guide (pdf) 