DynamicSignals / Kinetic Systems V266 32/64-Channel, 16-Bit D/A Converter

Features
  • 16, 32, or 64 Independent Analog Outputs
  • ±10 V, ±16 V, or 4-20 mA Output
  • 16-Bit Resolution
  • Low Drift
  • Single Gain and Offset Adjustments

Description

The Kinetic Systems V266 is a single-width, C-size, register-based, VXIbus module with 16, 32, or 64 16-bit analog output voltage channels. Several output options are available. The V266-ZA12 provides ±10 V full-scale outputs, the V266-ZB12 provides 4-20 mA current loop outputs and the V266-ZC12 provides ±16 V full scale. These options provide 32 output channels. Additionally, the V266-ZA22 and -ZA32 provide ±10 V full-scale outputs with a 64-channel density or 16-channel density respectively.

Data values for each channel are written to a 16-bit wide, dual-port memory. This memory is sequentially scanned, and the values are applied to a single 16-bit digital-to-analog converter. The DAC output is then multiplexed to separate high-precision sample-and-hold circuits (one for each channel), and the outputs of these circuits are fed through active, 2-pole, low-pass Bessel filters before being brought to the front panel connector. Bessel filters are provided because of their optimum step response. The nominal cutoff frequency of each filter is set at 500 Hz. Since the voltage outputs of all circuits are accurate to within 1 mV of each other, only one gain and one offset potentiometer are needed to adjust the DAC.

Data can be written to or read from the V266 in either offset binary or two's complement format as determined by the state of a bit in the control register. During power-on, the module initiates a sequence to zero the memory contents. The output signals are available at a pair of high-density connectors on the module's front panel. Paired output signals are provided to eliminate ground offset effects.

The V266 supports both static and dynamic configuration. Access to the dual-port memory is via memory locations indicated by the Offset Register within the VXIbus Configuration Register set through A24/A16 address space using D16 data transfers.


Important Notice: Please note that any additional items included with this equipment such as accessories, manuals, cables, calibration data, software, etc. are specifically listed in the above stock item description and/or displayed in the photos of the equipment. Please contact one of our Customer Support Specialists if you have any questions about what is included with this equipment or if you require any additional information.


Contact Us
Share:

Specifications

Contact Us
Share:

Item Images

Click a thumbnail to view larger image:

DynamicSignals / Kinetic Systems V266 32/64-Channel, 16-Bit D/A ConverterDynamicSignals / Kinetic Systems V266 32/64-Channel, 16-Bit D/A ConverterDynamicSignals / Kinetic Systems V266 32/64-Channel, 16-Bit D/A Converter
DynamicSignals / Kinetic Systems V266 32/64-Channel, 16-Bit D/A Converter


Contact Us
Share:

View It Live

View equipment LIVE - Before you buy!

InstraView™ Equipment Inspection



Buying used equipment doesn't always have to be a shot in the dark. We know there are plenty of differences when it comes to used equipment and quite often, choosing between different pieces is difficult, especially when the equipment is not sitting right in front of you.

Well, what if you were able to see a piece of equipment before you purchased it? Not just a picture from the manufacturer's website, but the actual piece of equipment you would receive.
With InstraView™, we move you one step closer to inspecting the equipment you're interested in without having to wait for the equipment to show up at your door.

InstraView™ works in your web browser and allows you to view the actual piece of equipment you're interested in before purchasing. You can zoom in close to see the labels with the serial number or zoom out to see the overall condition of the equipment.

It's like having the store come to you!


InstraView Request Form

To get started:

  1.   Fill in the request form below
  2.   We'll send you an email letting you know exactly when your piece of equipment will be available for viewing

Name:
Email:
Item to Inspect: 53799-2 - DynamicSignals / Kinetic Systems V751-ZA41 Front-panel Termination Assembly for the +/-16V 64-Channel V266


All you need is a web browser (ie. Microsoft Internet Explorer or Netscape) and Sun's Java Runtime Environment installed. If you need to install the Sun Java Runtime, you may download the latest Java SE Runtime Environment (JRE) http://www.oracle.com/technetwork/java/javase/downloads/index.html