Basler Electric D1 Dead Bus Module
  • Basler_Electric_D1_View1_20157311534
  • Basler_Electric_D1_View2_20157311534
  • Basler_Electric_D1_View3_20157311534

Basler Electric D1 Dead Bus Module







Have a quote from somewhere else? Click Here
Stock # 64832-3
Quick Quote
Sell Yours
Repair Quote
  • More Info
  • Tech Specs
  • Additional Photos
  • Datasheets / Manuals 
  • View It Live Request 
Contact Us
Share:
Basler Electric BE1-25A Automatic Synchronizer

Features
  • Multi-Generator Operation
  • Smooth Synchronizing with Minimum System Impact
  • Real-Time Adaptive Proportional Speed Control Algorithm
  • Highly Flexible Design
  • Control Multiple Systems

Description

BE1-25A

The BE1-25A Automatic Synchronizer is a microprocessor based system including features to bring any generator on line in a minimum time, from small diesel units to large difficult hydros. It may be configured for simple manual control systems or equipped for complete automatic control of generators. The BE1-25A initiates closure of the generator circuit breaker when voltage magnitude, slip frequency, and phase difference are within preset limits. This capability minimizes system transients that can result from differences in speed, voltage level, or phase angle at the instant of the breaker closure - transients that can damage the breaker and generating system. The BE1-25A has the ability to operate over a wide range of slip frequencies. This allows it to be used on virtually any type of prime mover, from very slow-responding, high inertia, hydro-turbines to fast-responding gas turbines and diesel engines.

A2 Voltage Acceptance Module

The A2 Voltage Acceptance Module can use as many as three voltage parameters to add constraints to the issuance of breaker command signals. This option is a prerequisite of, and a controller of, any voltage matching option that may be present. The upper Limit control establishes a maximum bus voltage. No closure is to be attempted when the bus voltage is above the upper limit. The lower limit control establishes a minimum bus voltage. No closure is to be attempted when the bus voltage is below the lower limit. The voltage difference control establishes the maximum acceptable voltage difference between the two sides of the circuit breaker (generator voltage minus bus voltage). No closure is to be attempted when the circuit breaker voltage difference is greater than the set limit. The voltage difference is continuously variable over the range of 1 to 10 Vac. An LED to the left of each control lights whenever the associated parameter is beyond the range set by the control. As a result, the breaker closure is inhibited.

D1 Dead Bus Module

When the external dead bus contact is closed, module D1 determines when the bus is dead, and acts upon this determination (if the breaker is detected open) by initiating a close breaker signal. This signal is terminated as soon as the sync acceptor recognizes the breaker as having closed, or when 100 milliseconds has passed (whichever occurs first). The Volts control defines a dead bus condition by establishing a voltage threshold between 10 and 40 Vac. The Dead Bus indicator is an LED that lights whenever the bus voltage is below the control setting.


Product Family: BE1-25A, BE1 25A, BE125A, BE 125A, BE-125A


Important Notice: Please note that any additional items included with this equipment such as accessories, manuals, cables, calibration data, software, etc. are specifically listed in the above stock item description and/or displayed in the photos of the equipment. Please contact one of our Customer Support Specialists if you have any questions about what is included with this equipment or if you require any additional information.


Contact Us
Share:

Specifications

Voltage SensingThe two sensing inputs–for the generator and the bus voltage–are designed to operate in the range of 70-150 Vac, 50/60 Hz. Burden is less than 6.0 VA for the generator input and less than 2.0 VA for the bus input
Power SupplyPower for the internal circuitry requires an external source rated at 90-132 Vac, 50/60 Hz (single phase), or 70-150 Vdc. Burden: Less than 20.0 VA.
Breaker Closing ContactMake and carry 30 A at 250 Vdc for 1 second, 7 A continuously, and break 0.3 A at 250 Vdc. L/R = 0.04.
Voltage, Frequency (Speed) Correction and Lockout ContactsMake and break 5 A at 250 Vac (80%PF), 5 A at 28 Vdc (resistive) and 0.5 A at 120 Vdc (resistive).
Relay Fail ContactMake and break 5 A at 250 Vac (80% PF), 5 A at 28 Vdc (resistive) and 0.5 A at 120 Vdc (resistive).
Surge Withstand CapabilityThe unit has been qualified to ANSI/IEEE C37.90.1-1989 Standard Surge Withstand Capability Tests; (Oscillatory and Fast Transient), IEC 255-5 Impulse Test and Dielectric Test.
Radio Frequency InterferenceMaintains proper operation when tested for interference in accordance with IEC C37.90-1989, Trial-Use Standard Withstand Capability of Relay Systems to Radiated Electromagnetic Interfence from Transceivers.


Contact Us
Share:

Item Images

Click a thumbnail to view larger image:

Basler Electric BE1-25A Automatic Synchronizer
BE1-25A
Basler Electric BE1-25A Automatic Synchronizer
BE1-25A
Basler Electric BE1-25A Automatic Synchronizer
BE1-25A
Basler Electric BE1-25A Automatic Synchronizer
BE1-25A


Contact Us
Share:

View It Live

View equipment LIVE - Before you buy!

InstraView™ Equipment Inspection



Buying used equipment doesn't always have to be a shot in the dark. We know there are plenty of differences when it comes to used equipment and quite often, choosing between different pieces is difficult, especially when the equipment is not sitting right in front of you.

Well, what if you were able to see a piece of equipment before you purchased it? Not just a picture from the manufacturer's website, but the actual piece of equipment you would receive.
With InstraView™, we move you one step closer to inspecting the equipment you're interested in without having to wait for the equipment to show up at your door.

InstraView™ works in your web browser and allows you to view the actual piece of equipment you're interested in before purchasing. You can zoom in close to see the labels with the serial number or zoom out to see the overall condition of the equipment.

It's like having the store come to you!


InstraView Request Form

To get started:

  1.   Fill in the request form below
  2.   We'll send you an email letting you know exactly when your piece of equipment will be available for viewing

Name:
Email:
Item to Inspect: 64832-3 - Basler Electric D1 Dead Bus Module


All you need is a web browser (ie. Microsoft Internet Explorer or Netscape) and Sun's Java Runtime Environment installed. If you need to install the Sun Java Runtime, you may download the latest Java SE Runtime Environment (JRE) http://www.oracle.com/technetwork/java/javase/downloads/index.html