Configuration:
• Voltage Range: 0 V to 200 V
• Current Range: 0 A to 17 A
• Voltage Programming Accuracy: 0.035%, +145 mV
• Current Programming Accuracy: 0.2%, +25 mA
• Voltage RMS: 22 mV
• Voltage Peak-to-Peak: 50 mV
• Current RMS: 15 mA
• Voltage Readback Accuracy: 0.08%, +80 mV
• Current Readback Accuracy: 0.36%, +15 mA




Stock # 71564-15




Configuration:
• Voltage Range: 0 V to 200 V
• Current Range: 0 A to 17 A
• Voltage Programming Accuracy: 0.035%, +145 mV
• Current Programming Accuracy: 0.2%, +25 mA
• Voltage RMS: 22 mV
• Voltage Peak-to-Peak: 50 mV
• Current RMS: 15 mA
• Voltage Readback Accuracy: 0.08%, +80 mV
• Current Readback Accuracy: 0.36%, +15 mA

Options:
• Option 001: Front panel only has line switch, line indicator, and OVP adjust.



Stock # 71564-16




Configuration:

• Voltage Range: 0 V to 20 V
• Current Range 0 A to 120 A
• Voltage Programming Accuracy: 0.035%, +15 mV
• Current Programming Accuracy: 0.25%, +250 mA
• Voltage RMS: 8 mV
• Voltage Peak-to-Peak: 50 mV
• Current RMS: 120 mA
• Voltage Readback Accuracy: 0.08%, +7 mV
• Current Readback Accuracy: 0.4%, +100 mA

Opt 120: 104 to 127 Vac, 47 to 63 Hz





Stock # 71564-4




Configuration:

• Voltage Range: 0 V to 60 V
• Current Range 0 A to 50 A
• Voltage Programming Accuracy: 0.035%, +40 mV
• Current Programming Accuracy: 0.2%, +85 mA
• Voltage RMS: 8 mV
• Voltage Peak-to-Peak: 40 mV
• Current RMS: 25 mA
• Voltage Readback Accuracy: 0.08%, +20 mV
• Current Readback Accuracy: 0.36%, +35 mA



Stock # 71564-3




Configuration:

• Voltage Range: 0 V to 60 V
• Current Range 0 A to 10 A
• Voltage Programming Accuracy: 0.035%, +40 mV
• Current Programming Accuracy: 0.09%, +10 mA
• Voltage RMS: 3 mV
• Voltage Peak-to-Peak: 30 mV
• Current RMS: 5 mA
• Voltage Readback Accuracy: 0.07%, +50 mV
• Current Readback Accuracy: 0.2%, +11 mA





Stock # 71564-2




The hardware surrounding the power light is missing; however, this does not affect the units functionality.

Configuration:

• Voltage Range: 0 V to 60 V
• Current Range 0 A to 10 A
• Voltage Programming Accuracy: 0.035%, +40 mV
• Current Programming Accuracy: 0.09%, +10 mA
• Voltage RMS: 3 mV
• Voltage Peak-to-Peak: 30 mV
• Current RMS: 5 mA
• Voltage Readback Accuracy: 0.07%, +50 mV
• Current Readback Accuracy: 0.2%, +11 mA

Options:
• Option 001: Front panel has only line switch, line indicator, and OVP adjust.

View Photo of Power Light




Stock # 71564-1




This is a refurbished unit from the original manufacturer.

Configuration:

• Voltage Range: 0 V to 60 V
• Current Range 0 A to 50 A
• Voltage Programming Accuracy: 0.035%, +40 mV
• Current Programming Accuracy: 0.2%, +85 mA
• Voltage RMS: 8 mV
• Voltage Peak-to-Peak: 40 mV
• Current RMS: 25 mA
• Voltage Readback Accuracy: 0.08%, +20 mV
• Current Readback Accuracy: 0.36%, +35 mA





Stock # 71564-6




This unit is sealed in the original manufacturer's box.

Configuration:

• Voltage Range: 0 V to 60 V
• Current Range 0 A to 50 A
• Voltage Programming Accuracy: 0.035%, +40 mV
• Current Programming Accuracy: 0.2%, +85 mA
• Voltage RMS: 8 mV
• Voltage Peak-to-Peak: 40 mV
• Current RMS: 25 mA
• Voltage Readback Accuracy: 0.08%, +20 mV
• Current Readback Accuracy: 0.36%, +35 mA



Stock # 71564-5



  • Description
  • Tech Specs
  • Datasheets / Manuals 
Contact Us
Share:

Description

The Agilent / HP 603xA Series System Autoranging DC Power Supplies offer essential features for a tight budget. The single-output, autoranging 200 W and 1000 W GPIB 6030A-6033A, 6035A, and 6038A provide analog/resistance control of output voltage and current; series and auto-parallel connections of multiple supplies; and built-in measurements and advanced programmable features.

Product Family: 6030A, 6031A, 6032A, 6033A, 6035A, 6038A, 6030, 6031, 6032, 6033, 6035, 6038
Contact Us
Share:

Specifications

Contact Us
Share:

Resources

Manuals, Datasheets, Drivers, Links

Agilent / HP 603xA Datasheet (pdf) 
Agilent / HP 603xA Manual (pdf) 
Link to Keysight / Agilent Website