This Agilent / Acqiris DP211 / U1068A-002 High-Speed PCI Digitizer is used and in excellent condition. This unit has an Acqiris XP100 fan installed.

Configuration:
• Input: Dual




Have a quote from somewhere else? Click Here
Stock # 89351-1
Quick Quote
Sell Yours
Repair Quote
  • More Info
  • Tech Specs
  • Additional Photos
  • Datasheets / Manuals 
  • View It Live Request 
Contact Us
Share:
Agilent / Acqiris DP210 / DP211 / U1068A High-Speed PCI Digitizers

Features
  • 2 GS/s Sampling Rate
  • 500 MHz Bandwidth
  • 256 kSample Acquisition Memory
  • Single-Channel or Dual-Input Front-End
  • 50 Ω and 1 MΩ Input Impedance
  • < ±2% DC Accuracy for Precise Voltage Measurement
  • DP211 / U1068A-002
  • DP210 / U1068A-001

Description

The Agilent / Acqiris DP210 / DP211 / U1068A High-Speed PCI Digitizers are designed for the specific purpose of optimizing high-speed ADC performance. The analog front-end technology provides the signal conditioning, amplification, and interleaving functions essential to achieving high-speed data acquisition at GS/s rates. The digital data handling components provide vital clock and synchronization signals, to capture and memorize acquired data with maximum throughput. Together these ASICS make low-power, high-fidelity, data acquisition much more accessible and provide maximum data throughput to the host PC or processor to reduce the time and cost of measurement.

The Agilent / Acqiris DP210 / DP211 / U1068A High-Speed PCI Digitizers deliver 2 GS/s single-shot sampling rate, wide 500 MHz bandwidth, and long 256-ksample acquisition memory. The high sampling rate and wide bandwidth combine to allow the accurate capture of signals up to 500 MHz in frequency. The long acquisition memory enables the digitizer to record complex signals over long periods of time.

The Agilent / Acqiris DP210 / DP211 / U1068A High-Speed PCI Digitizers has programmable front-end electronics that provide a complete set of input voltage ranges (from 50 mV to 5 V, full scale, in a 1, 2, 5 sequence) and variable voltage offset. The input has selectable impedance (50 Ω or 1 MΩ) and is fully protected against over-voltage signals. The amplifiers feature internal calibration (no need to disconnect input signals) and very fast recovery from out-of-range signals. The input buffer is mounted on a removable mezzanine card so replacement is fast and efficient, in the event of accidental damage or as components fatigue over time (such as relays in high-duty-cycle automated testing applications).

The digitizer includes a precision trigger system with full pre- and post-trigger adjustment. User-selectable coupling is combined with internal or external trigger sources for maximum flexibility. The digitizer also provides a sophisticated sequential trigger mode with less than 500 ns dead time between successive triggers. This extremely low dead time enables events, that may occur at high repetition rates, to be captured and stored in their correct arrival sequence. This trigger mode is perfect for "impulse-response" type applications (radar, sonar, LIDAR, ultrasonic, medical and biomedical research, etc.). The sequential trigger mode and low dead time greatly extend the digitizers' timing range and resolution. Each event can be individually time stamped and relative time measurements (between events) can be made with less than 1-ns resolution.

Each digitizer has its own crystal-controlled precision time base, and sample rates can be selected, in a 1, 2, 2.5, 4, 5 sequence, from 100 S/s to 2 GS/s. An internal time-to-digital converter (TDC) with high timing resolution is used to assist with timing calibration and trigger positioning. The TDC permits accurate positioning of the trigger signal with regard to the internal clock (sampling time). The sample rate can also be generated externally using the external input connector for applications where the sample rate must be synchronized with the signal to be acquired.


Product Family: DP210, DP21O, DP211, DP2II, U1068A, UI068A, U1O68A, UIO68A


Important Notice: Please note that any additional items included with this equipment such as accessories, manuals, cables, calibration data, software, etc. are specifically listed in the above stock item description and/or displayed in the photos of the equipment. Please contact one of our Customer Support Specialists if you have any questions about what is included with this equipment or if you require any additional information.


Contact Us
Share:

Specifications

Contact Us
Share:

Item Images

Click a thumbnail to view larger image:

Agilent / Acqiris DP210 / DP211 / U1068A High-Speed PCI DigitizersAgilent / Acqiris DP210 / DP211 / U1068A High-Speed PCI DigitizersAgilent / Acqiris DP210 / DP211 / U1068A High-Speed PCI Digitizers


Contact Us
Share:

View It Live

View equipment LIVE - Before you buy!

InstraView™ Equipment Inspection



Buying used equipment doesn't always have to be a shot in the dark. We know there are plenty of differences when it comes to used equipment and quite often, choosing between different pieces is difficult, especially when the equipment is not sitting right in front of you.

Well, what if you were able to see a piece of equipment before you purchased it? Not just a picture from the manufacturer's website, but the actual piece of equipment you would receive.
With InstraView™, we move you one step closer to inspecting the equipment you're interested in without having to wait for the equipment to show up at your door.

InstraView™ works in your web browser and allows you to view the actual piece of equipment you're interested in before purchasing. You can zoom in close to see the labels with the serial number or zoom out to see the overall condition of the equipment.

It's like having the store come to you!


InstraView Request Form

To get started:

  1.   Fill in the request form below
  2.   We'll send you an email letting you know exactly when your piece of equipment will be available for viewing

Name:
Email:
Item to Inspect: 89351-1 - Agilent / Acqiris DP211 / U1068A-002 High-Speed PCI Digitizer


All you need is a web browser (ie. Microsoft Internet Explorer or Netscape) and Sun's Java Runtime Environment installed. If you need to install the Sun Java Runtime, you may download the latest Java SE Runtime Environment (JRE) http://www.oracle.com/technetwork/java/javase/downloads/index.html