The Pilz PSS 3032 is a compact safety system within a single housing. Connections are made via screw terminals. The system can be connected to other controller types via I/Os or via a serial(...) interface. Safety systems in the PSS-range are divided into a failsafe section and a standard section. Safety-related functions can only be processed through the failsafe section. The failsafe and standard sections communicate without feedback, i.e. potential program errors in the standard section will not affect the safety section. The failsafe section of the CPU operates through three diverse channels, ensuring a high level of safety. All inputs and outputs are processed separately by each channel. Each channel compares the result with the two adjacent channels. Input and output signals are only valid if all three channels reach the same result (3oo3). The PSS 3032 has an integral Flash-EPROM program memory with 64 KByte for both the standard and failsafe section. The unit has two serial interfaces: an RS 232 interface that is available to the user, and an RS 485 that is used for programming.
This Pilz PSS SB DI8OZ4 Decentralized Digital I/O Circuit is used and in excellent condition. This may or may not have all screw terminal blocks installed.
Configuration: (...)• Digital Inputs: 8 • Supply Voltage: 24 VDC • Positive-Switching Digital Outputs: 4 • Negative-Switching Digital Outputs: 4
The Pilz PSS1 DI2O T has digital input and output circuits / test pulses with integral software algorithms and redundant design for safety-related functions.
(...)Configuration: • Inputs: 16 digital • Outputs: 16 digital (2 Amp) or pulsed
The Pilz PSS 1 SB CPU has Central processing unit with integral test algorithms and redundant design, for use as part of a modular safety-related system with connection to SafetyBUS. (...) Model Number: PSS 1 SB CPU ZENTRALEINHEIT
The Pilz PSS1 DI2O T has digital input and output circuits / test pulses with integral software algorithms and redundant design for safety-related functions.
(...)Configuration: • Inputs: 16 digital • Outputs: 16 digital (2 Amp) or pulsed
The PSS1 BMP 5/2 is a module rack designed for the mechanical installation of PSS 3100 modules and for the internal electrical wiring of the safety-related system. The module rack has a redundant(...) bus for installing failsafe modules such as the PSS1 DI2 or PSS1 DO. Slots 0 and 1 also have a single-channel bus for installing standard modules such as the PSS1 IBS-S PCP or PSS1 DP-S communications modules or, for example, the P9 DI or P9 DO.
This does NOT include a PSS1 PS 24 power supply. They are sold separately.
The battery is used. The Pilz PSS1 PS 24 Power Supply Module has integral protection and monitoring circuits, for use as part of a modular safety-related system.
(...)Configuration: • Supply Voltage: 24VDC
Model Number: PSS1 PS 24 Netzteil Fail-Safe+Standard
The Pilz PSS1 DIO Z has dual-pole switching input and output circuits with integral software algorithms and redundant design for safety-related functions.
(...)Configuration: • Digital Inputs: 16 • Digital Outputs 8 (Dual-Pole, 2 Amp)
The PSS CPU is to be used with the PSS 3000 safety system. The PSS CPU controls the integral on-board and, where necessary, decentralized periphery modules. It processes and stores the user program(...) and variable data.
This Pilz PSS SB DI16 Digital I/O Module is used and in good condition. The housing on this unit is chipped; however, this does not affect its ability to function properly. (...) Configuration: • Digital Inputs: 16 • Test Pulse Outputs: 4 • Supply Voltage: 24 VDC
The Pilz PSS1 PS 24 Power Supply Module has integral protection and monitoring circuits, for use as part of a modular safety-related system. Battery has unknown remaining life.
The PSS SB 3006 CN-A is a compact safety system with SafetyBUS p and Interbus interface, suitable for safety-related functions because of its multi-channel diverse structure.
(...)Configuration: • 6 Digital Inputs • Data Memory (Failsafe Section/Standard Section): 16 KB / 170 KB • Program Memory (Failsafe Section/Standard Section): 256 KB / 512 KB
The PSS1 CPU2 controls the integral on-board and, where necessary, decentralized periphery modules. It processes and stores the user program and variable data. (...) Part Number: PSS1 CPU2 ZENTRALEINHEIT (PSS1 CPU2 Central Unit)
The hinge on the front panel is broken. The Pilz PSS1 DI2O Z has dual-pole switching input and output circuits with integral software algorithms and redundant design for safety-related functions.(...)
Configuration: • Inputs: 16 digital • Outputs: 16 digital
The Pilz PSS 3032 is a compact safety system within a single housing. Connections are made via screw terminals. The system can be connected to other controller types via I/Os or via a serial(...) interface. Safety systems in the PSS-range are divided into a failsafe section and a standard section. Safety-related functions can only be processed through the failsafe section. The failsafe and standard sections communicate without feedback, i.e. potential program errors in the standard section will not affect the safety section. The failsafe section of the CPU operates through three diverse channels, ensuring a high level of safety. All inputs and outputs are processed separately by each channel. Each channel compares the result with the two adjacent channels. Input and output signals are only valid if all three channels reach the same result (3oo3). The PSS 3032 has an integral Flash-EPROM program memory with 64 KByte for both the standard and failsafe section. The unit has two serial interfaces: an RS 232 interface that is available to the user, and an RS 485 that is used for programming.
The PSS1 CPU controls the integral on-board and, where necessary, decentralized periphery modules. It processes and stores the user program and variable data. (...) Model Number: PSS1 CPU ZENTRALEINHEIT (PSS1 CPU Central Unit)
The Pilz PSS1 DIO Z has dual-pole switching input and output circuits with integral software algorithms and redundant design for safety-related functions.
(...)Configuration: • Digital Inputs: 16 • Digital Outputs 8 (Dual-Pole, 2 Amp)
The PSS1 BMP 5/2 is a module rack designed for the mechanical installation of PSS 3100 modules and for the internal electrical wiring of the safety-related system. The module rack has a redundant(...) bus for installing failsafe modules such as the PSS1 DI2 or PSS1 DO. Slots 0 and 1 also have a single-channel bus for installing standard modules such as the PSS1 IBS-S PCP or PSS1 DP-S communications modules or, for example, the P9 DI or P9 DO.
Chassis Part Number: 302006 Installed Power Module: PSS1 PS 24 Power Module Part Number: 302051
View Photo of the opened front panel of the PSS1 PS 24.
*If a specific memory size is required, please contact Artisan Technology Group Sales for pricing and availability. Otherwise, memory sizes will be within the specified range.