This Danaher Motion / Kollmorgen PSR4/5A-250 Power Supply with Regeneration is used and in excellent condition.
Configuration:
• Power Supply Generation Indicator: U.L. 508 Listed Configuration, Used with BDS4A Series Servo Motor Amplifiers
• AC Line Voltage: 230 VAC; 3 Phase
• AC Line Current, RMS: 50
• Mechanical Options: Standard, No Options
• Electrical Options: Standard. No Options. 12 and 20 Amp Models Contain 40 Watt Internal Regeneration Resistor. 50 and 75 Amp Models Require Regeneration Resistor Kit EX-2X (May be ordered separately from the manufacturer)
Show More Description
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Features:
- Modular Construction Maximizing Serviceability
- Two-part Plug Connectors Interfacing Between the BDS4, PSR4/5 and Other Equipment
- Contains a Soft Start Function and a Dynamic Bus Discharge Function
- Diagnostic LED Indicators
The Danaher Motion / Kollmorgen PSR4 Series Power Supply with Regeneration is divided into four (4) main sections:
1. The Unregulated Logic Bus, supplied by the Control AC line input voltage (normally single-phase 115 VAC.
2. The 310/140 Main DC Bus is supplied by the main AC line input voltage (normally three-phase 230 VAC or single-phase 115VAC).
3. The Soft-Start Feature (standard) resistor limits the inrush current (to charge-up the Main Bus Capacitors).
4. The Shunt Regulator (regeneration) section includes circuitry which monitors the main bus. During deceleration profiles, the motor basically operates as a DC generator and pumps energy back into the main bus causing the bus to rise. The Shunt Regulator limits the voltage rise during the deceleration periods.
12 and 20 AMP Models: The shunt regulator (regeneration) resistor load is fuse protected. If the shunt regulator is held on for too long, the shunt regulator power transistor fails, or the shunt regulator load resistor becomes shorted, the fuse will blow and cause the Fault Contact on the PSR4 to open and the BLOWN REGEN FUSE LED to become illuminated.
The shunt regulator also includes a duty cycle limit circuit to protect against excessive load resistor heating. If the average duty cycle limit is exceeded, the regeneration circuitry will become disabled, the Fault Contact will open, and the OVERLOAD LED will become illuminated. To reset this fault, remove and reapply all input line power; bus capacitors must completely discharge.
50 and 75 AMP Models: The shunt regulator (regeneration) resistor is protected by a thermal overload relay. If the resistor rating is exceeded or if the shunt regulator transistor fails, the thermal overload output contacts will open indicating an IMMEDIATE need to remove the main power.
Artisan Scientific Corporation dba Artisan Technology Group is not affiliated with or a distributor for Danaher Motion / Kollmorgen. The depiction, description, or sale of products featuring names, trademarks, brands, and logos is for identification and/or reference purposes only and does not indicate any affiliation with or authorization by any rights holder.
Great company staff is extremely knowledgeable!!
Staff knows their stuff! Very knowledgeable and helpful. Very satisfied!
We found Artisan when our PXI Chassis broke, which shut down our production line. We were up and running in less than a day because they shipped overnight and talked our tech guys through the installation over the phone. ATG saved the day big time!
I just want to thank you and the staff at Artisan for your prompt dispatch of the 34401A main board. I got it a couple of hrs. ago, removed the old board, installed the new and the result is as shown in the attachment. It not only works, but is calibrated to the last digit! I am very pleased and will definitely recommend your firm to my friends and colleagues. I really appreciate doing business with a firm that values service.