This Newport 818-F-IR Fiber Optic Detector Module 780-1800 nm with 818-FA3-FC Fiber Adaptor is used and in good condition. The housing on this unit is scratched; however, this does not affect its ability to function properly.
View Photo of the scratched housing.
Show More Description
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Features:
- Power Levels from pW to 2W
- Wavelengths from 190-1800 nm
- Proprietary Detector Optics
- Patented, Matched OD3 Attenuator
- EMI/RFI Shielded
- Free-Space and Fiber Optic Versions
The Newport 818 Series Low-Power Detectors uses the highest quality semiconductor detector materials available.
The 818 Series Cylindrical Detectors (818-UV, 818-SL, 818-IR, 818-IG) are offered for broad wavelength ranges covering UV, visible, near-IR, and IR regions. They use the finest large-area planar-diffused PIN silicon, indium gallium arsenide, germanium PIN or inverted-channel silicon detectors. Each is optimized for zero-bias operation to provide the low noise, high stability and uniformity demanded by critical radiometric measurements. Compact packaging, international mounting holes and BNC-terminated cabling make incorporation into experimental, production and field applications straightforward.
The 818-F Series Fiber Optic Detector Modules are optimized for measurements on connectorized fiber optics. These compact detector modules allow the connection of an optical fiber directly to the meter, configuring it as a dedicated fiber optic power meter. These detector modules are only compatible with Newport meters that support the /CM detector option. They are not BNC- terminated.
Exclusive OD3 attenuator technology extends the calibrated optical dynamic range of the Cylindrical and Hand-Held Wand Detectors by three decades. The patented attenuator design provides low reflection, high damage threshold and spectral flatness, without the damage susceptibility problems of thin-film attenuators or the spectral variance of simple volume- absorbing attenuators
Calibration modules are required when using Cylindrical and Hand-Held Wand Detectors with Newport’s Model 840-C, 1830-C, 1835-C, 2832-C, 2835-C or 4832-C optical meters. The module is matched to an individual detector and provides the meter with detector calibration and operating information. The calibration module option is indicated by the /CM suffix in the detector Model number.
When using Cylindrical or Hand-Held Detectors with Newport's 841-PE Power/Energy Meter, a DB15 connector with EEPROM is required. This option is indicated by the /841 suffix.
Artisan Scientific Corporation dba Artisan Technology Group is not affiliated with or a distributor for Newport. The depiction, description, or sale of products featuring names, trademarks, brands, and logos is for identification and/or reference purposes only and does not indicate any affiliation with or authorization by any rights holder.
Excellent customer service!
I found that the staff is very knowledgeable. I would recommend them to anyone looking for this type of equipment!
We have some test equipment in our lab from the 1990's that stopped working about 2 years ago. It sat in the corner collecting dust, but we took on a project last month that required more machines. After talking to Artisan, we found out we could get parts to fix our machine for much less than buying a new one!
Don’t worry about damage to your items during shipping – the box ours came in could have taken a beating and would have still survived!