5301HA1S8E5AM00340DAE6M1C1Q4Q8QS:
• 5301- Guided Wave Radar Liquid Level or Interface Transmitter (Interface Available for Fully Submerged Probe)
• H- Signal Output: 4-20 mA with HART Communication (Default Output from Factory is HART 5)
• A- Housing Material- Polyurethane-Covered Aluminum
• 1- Conduit / Cable Threads: ½ - 14 NPT
• S- Operating Temperature and Pressure: Standard -15 to 580 psig @ 302 °F (-1 to 40 bar @ 150 °C)
• Probe Type: 1A, 2A, 3A, 3B, 4A, 4B, 4S, 5A, and 5B
• 8- Material of Construction:
• Process Connection / Probe: PTFE Covered Probe
• Probe Type: 4A and 5A
• Valid Operation Temperature and Pressure: S
• E- Sealing, O-Ring Material: Ethylene Propylene (EPDM)
• 5A- Probe Type: Flexible Single Lead with Weight
• Process Connections: Flange / 1-in., 1½ -in., 2-in. Thread / Tri Clamp
• Probe Lengths: Min: 3 ft. 4 in. (1 m) Max: 164 ft. (50 m)
• M: Probe Length Units: Metric (Meters, Centimeters)
• 003- Total Probe Length (feet/m): 3 ft. / 1m
• 40- Total Probe Length (in./cm): 40 in / 101.6cm
• DA- Process Connection - Size / Type:
• ASME Flanges: 6-in. Class 150, RF (Raised Face Type)
• Material of Construction: 1, 2, 3, 7, 8, H
• Operating Temperature and Pressure: S, H, P, C
• E6- Hazardous Locations Certifications: CSA Explosion-Proof
• M1- Display: Integral Digital Display
View Photo of the ½ - 14 NPT nut.